Active barrier
3. Electrical connection
3.1 Terminal layout
Teminal layout
L/+
L for AC
+ for DC
N/-
N for AC
- for DC
Ground (PE)
O+
Measurement signal +
O-
Measurement signal -
Measurement signal + with integrated HART
O+H
communication resistance (250 Ω)
I+
Measurement signal +
I-
Measurement signal -
®
HART
- communication to
®
HART
SMART transmitter
3.2 Power supply connection
- Before installing the unit please check that the power supply
corresponds with that shown on the unit legend plate.
- When operating with a 90...253 V AC unit a power isolator must
be situated within easy reach of the unit, this should also be fused
with at least 10 A.