1. Scope of delivery
1.1
Installation set
(see Figure 1)
Fig. 1
• Filter head (1) with female thread for the con-
nection to the filter cartridge. The head is
fitting to different Woda-Pure sizes. An aqua
stop and two non return valves (inlet and out-
let) are installed in the filter head.
• Wall bracket (2) to mount the filter cartridge.
• Filter cartridge (3) with hygienic cap and male
thread as counterpart to the filter head (1).
• Installation
and
Manual
1.2 Replacement filter cartridge
Filter cartridge (3) with hygienic cap and male
thread as counterpart to the filter head (1).
For hygienic reasons all parts are wrapped in a
protection foil.
2. Technical data
2.1 Dimensions and weights
(see Fig. 2)
Woda-Pure
Total height without bracket, max. (A)
Total height with bracket (B)
Height to centre of connection (C)
Distance required for service (D)
Installation length (E)
Filter cartridge Ø (F)
Weigth of filter cartridget, dry (approx.)
Weight of filter cartridge, wet (approx.)
10
Operating
Instructions/
M
mm 465-475
mm
500
mm
421
mm
65
mm
125
mm
130
kg
2.4
kg
4.2
Fig. 2
2.2 Operation conditions
Woda-Pure
Inlet/Outlet fittings
Typical capacity
Nominal flow rate
Working pressure, min-max
Required water pressure inlet
Pressure drop at 47.5 US gallons/h
(180 Litres/h)
1
Water temperature, min-max.
Ambient temperature, min-max.
Transportation and storage ambient
temperature, min-max.
Operation/Installation position
1
At bypass setting „2" with a 1.5 hose DN8 fitted to both the intake and
outlet.
NOTE!
• We recommend to replace the filter after
6 months after installation regardless of the
remaining capacity.
• After a shut down period of longer than
4 weeks, the filter cartridge has to be repla-
ced in any case.
3. General information
3.1 Information about this installation and
operation manual
This installation and operation manual provides
the necessary information for the correct instal-
lation and operation of the filter system.
Please make sure that the installation complies
with applicable state and local regulations for
the operation, safety and installation and for the
disposal of used filter systems as well.
M
3/8"
L
4500
L/h
60
bar
2 - 8
bar
> 1.2
bar
0.4
°C
+4 to +30
°C
+4 to +40
°C
-20 to +40
vertical