Person
1)
Operating company
Competent expert /
inspector (familiar with,
understands oper-
ating instructions)
Competent skilled per-
son (specialist crafts-
man, in accordance with
installation instructions
and execution standards)
General inspector (in
accordance with EN 1825)
Qualified electrician (accord-
ing to national regula-
tions for electrical safety)
1) Operation and assembly work may only be carried out by persons who are 18 years of age.
2.3
Intended use
The product is a system for separating grease out of domestic or commercial wastewater according to EN 1825. Greases
are substances of vegetable origin and/or animal origin with a density of less than 0.95 g/cm³, which are partially or com-
pletely insoluble in water or are saponifiable. Disposal and maintenance cycles must be complied with for correct operation.
The separators are only intended for installation in the ground outdoors under defined conditions, see "Assembly" chapter.
All water-carrying components of the product must be installed at frost-free depth (for all-year use).
Only the extension sections supplied with the separator may be used, and only if the ambient conditions allow. In cases of
installation in areas of high ground water levels, the groundwater pressure must be taken into consideration.
WARNING
The tank of the separator does not have to be accessed for installation or maintenance purposes.
Nonetheless, if it is necessary to access a tank for unforeseen reasons, all the safety measures for entering cham-
bers must be taken (including testing the air to ensure that it is safe, and forced (mechanical) ventilation of the tank
if necessary, safety harnesses, tripod and look-out personnel.)
The stability of the tank is only ensured for its self-weight, transport and the described installation, in accordance with the
intended use (e.g. load class, road construction). Additional loads from single strip footings, or other external actions must be
avoided. If such actions are to be expected, it may be necessary to take special measures.
All:
modifications or attachments
use of non-genuine spare parts
repairs carried out by companies or persons not authorised by the manufacturer
without the express and written approval of the manufacturer can lead to a loss of warranty.
2.4
Product description
The EasyCleanground GW grease separator, installed in the ground, is available in nominal sizes 1, 2, 3, 4, 7, 8.5, 10 and
12.5. On request, the separator can be purchased as the Direct version with preassembled direct disposal pipe for perma-
nently installed disposal pipes.
We recommend installing the system with a continuously rising cable duct, just in case. It is then possible to retrofit a grease
layer thickness measuring device at any time.
Disposal cycles can then be undertaken in line with demand.
22 / 112
Approved activities on KESSEL systems
Visual check
Emptying, clean-
ing (inside), func-
tional check
Installation and operating instructions
Installation, replace-
ment, maintenance
of components,
commissioning
Leak test, checking
on correct design and
proper assembly before
initial commissioning
Work on electrical
installation
016-310