Warning:
The purchaser should make the manufacturer aware of any external effects or aggressive substances that the equipment may be
exposed to.
The cable glands shall only be used for fixed installations, the cables must be fixed to prevent pulling or twisting.
Important Notice: In case a failure of the safety system is detected either during operation or during routine maintenance when
executing a function test the unit should be switched off and taken out of service. Defects in the safety system cannot be repaired
in the field. Defective units are to be replaced and returned to the manufacturer for investigation. Please contact your nearest
nVent representative for more instructions. A list of worldwide representations can be found on the last page of this document or on
nVent.com/RAYCHEM
Please read all instructional literature carefully and thoroughly before starting.
Notice: The information contained in this document is subject to change without notice. Please read these Installation Instructions
before commissioning the instrument. Keep the instructions in a place which is always accessible to all users. Please assist us to
improve these instructions, where necessary. We are always grateful for your suggestions. Should any difficulties arise during
start-up, you are asked not to carry out any unauthorized manipulations on the instrument as this could affect your warranty rights!
Please contact the nearest nVent subsidiary or the head office. If any servicing is required, the instrument must be returned to the head
office.
Special conditions for safe use
Cable entry shall be Ex eb and tb ATEX certified and rated minimum IP66 to maintain the IP66 rating of the enclosure. Cable entry
devices must have a seal or gasket to provide sealing with the enclosure.
Unused cable entries must be filled with Ex eb and tb ATEX certified and rated minimum IP66 stopping plugs to maintain the IP66
rating of the enclosure. Cable entry plugs must have a seal or gasket to provide sealing with enclosure.
Not more than one single or multiple strand wiring lead shall be connected into either side of the terminals.
Leads connected to the terminals shall be insulated for the appropriate voltage and this insulation shall extend to within 1 mm of the
metal of the terminal throat.
The maximum permitted current of the non-IS alarm contacts is 3 A.
The earth pillar adjacent to the RTD connectors must be used only for RTD cable screens.
The external RTDs must be capable of withstanding a 500 V test to earth.
Certification
nVent certifies that this product met its published specifications at the time of shipment from the factory.
Warranty
This nVent product is warranted against defects in material and workmanship for a period of 12 months from the date of installation
or 30 months maximum from the date of shipment, whichever occurs first. During the warranty period, nVent will, at its option, either
repair or replace products that prove to be defective. For warranty service or repair, this product must be returned to a service facility
designated by nVent. The Buyer shall prepay shipping charges to nVent and nVent shall pay shipping charges to return the product to the
Buyer. However, the Buyer shall pay all shipping charges, duties, and taxes for products returned to nVent from another country.
nVent warrants that the software and firmware designated by nVent for use with a product will execute its programming instructions
properly when installed on that product. nVent does not warrant that the operation of the hardware, or software, or firmware will be
uninterrupted or error-free.
Limitation of warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Buyer, Buyer-supplied
software or interfacing, unauthorized modification or misuse, operation outside of the specifications for the product, or improper
installation.
NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. NVENT DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
Exclusive remedies
THE REMEDIES PROVIDED HEREIN ARE THE BUYER'S SOLE AND EXCLUSIVE REMEDIES. NVENT SHALL NOT BE LIABLE FOR ANY
DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER
LEGAL THEORY.
Statement of compliance
This equipment has been tested and found to comply with the low voltage directive 2014/35/EU, the ATEX directive 2014/34/EU and
the electromagnetic compatibility directive 2014/30/EU. These limits are defined to provide reasonable protection against harmful
interference in a residential installation (technical data mentions industrial application). This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
|
nVent.com/RAYCHEM