INsTALLATIoN
Commissioning
f Insert the power cable plug, if present, into the standard
f
safety socket or set the fuse/MCB.
f Check the function of the appliance.
f
f In the case of oversink installation, affix the company logo
f
supplied over the existing company logo.

11.2 Appliance handover

f Explain the appliance function to users and familiarise them
f
with its operation.
f Make users aware of potential dangers, especially the risk of
f
scalding.
f Hand over these instructions.
f

11.3 Recommissioning

Material losses
!
Following an interruption of the water supply, recommis-
sion the appliance by carrying out the following steps,
in order to prevent irreparable damage to the bare wire
heating system.
f Isolate the appliance from the power supply. Pull the power
f
cable plug, if present, from the socket, or remove the fuse/
reset the MCB.
f See chapter "Initial start-up".
f
www.stiebel-eltron.com

11.4 Settings

You can alter the maximum flow rate and temperature.
DANGER Electrocution
The flow rate and temperature may only be adjusted if
the appliance is isolated from the power supply.
f Isolate all poles of the appliance from the power supply.
f
DANGER Electrocution
The adjusting screw for changing the flow rate and the
potentiometer for setting the temperature are live if the
appliance has not been isolated from the power supply.
DEM |
43