Herunterladen Diese Seite drucken

Bender RDC104 Handbuch Seite 14

Werbung

RDC104
Klimaklasse
Ortsfester Einsatz (IEC 60721-3-3) .....................................................
...............................3K24 (außer Kondensation, Wasser und Eisbildung)
Transport (IEC 60721-3-2) .............................................................. 2K11
Langzeitlagerung (IEC 60721-3-1) ................................................. 1K21
Mechanische Beanspruchung
Ortsfester Einsatz (IEC 60721-3-3) ................................................ 3M11
Transport (IEC 60721-3-2) ............................................................... 2M4
Langzeitlagerung (IEC 60721-3-1) ................................................ 1M12
Einsatzhöhe ............................................................................ < 4000 m
Schutzart
RDC104 ............................................................................................ IP00
Anschlüsse
Ein-/Ausgänge
Anschlussart ..........................Leiterplattensteckverbinder 0,5 x 0,5 mm
Anordnung der Anschlüsse ....................................zweireihig 2 x 4 Pins
Rastermaß ...............................................................................2,00 mm
Kontaktoberfläche .................................................................... verzinnt
Stiftlänge ....................................................................................2,5 mm
Lötverfahren für PCB .................................Empfehlung: selektives Löten
Anschluss Messstromwandler CTBC17
Maximaler Abstand zu Steckverbinder ......................................100 mm
Hersteller Typenbezeichnung ........................Molex MicroFit 3.0 Header
Artikelnummer ....................................................................43045-0607
Der Steckverbinder ist nicht Bestandteil des Lieferumfangs. Weitere
Informationen sind dem von Molex erstellten Original-Datenblatt zu
entnehmen.
Normen
Die Überwachungsmodule entsprechen, je nach
Variante, den folgenden Gerätenormen:
RDC104-4:
IEC
62955
Fehlergleichstrom-Überwachungsein-
richtung zur Verwendung mit der Ladebetriebsart 3 von
Elektrofahrzeugen
Patente
EP 2 571 128 / US 9,397,494 / ZL 201210157968.6 / CN
103001175, EP 2 813 856
14
RDC104-4_D00402_03_M_DEEN / 08.2023
Climatic class
Stationary use (IEC 60721-3-3) ..........................................................
........................3K24 (except condensation, water and formation of ice)
Transport (IEC 60721-3-2) .............................................................. 2K11
Long-term storage (IEC 60721-3-1) ............................................... 1K21
Classification of mechanical conditions
Stationary use (IEC 60721-3-3) ..................................................... 3M11
Transport (IEC 60721-3-2) ............................................................... 2M4
Long-term storage (IEC 60721-3-1) .............................................. 1M12
Range of use ........................................................................... < 4000 m
Degree of protection
RDC104 ............................................................................................ IP00
Connections
Inputs/outputs
Connection type ............................ PCB plug-in connector 0.5 x 0.5 mm
Arrangement of connections ................................ double row 2 x 4 pins
Modular dimensions ................................................................2.00 mm
Contact surface ............................................................................tinned
Pin length ...................................................................................2.5 mm
Soldering process for PCB..................recommended: selective soldering
Connection measuring current transformer
CTBC17
Maximum distance to connector ..............................................100 mm
Manufacturer type designation .....................Molex MicroFit 3.0 Header
Article number ....................................................................43045-0607
The connector is not included in the scope of delivery. For further infor-
mation, refer to the original data sheet created by Molex.
Standards
The monitoring modules compliens, depending on the
variant, with the following device standards:
RDC104- 4:
IEC 62955 Residual direct current detecting device
(RDC-DD) to be used for mode 3 charging of electric
vehicles)
Patents
EP 2 571 128 / US 9,397,494 / ZL 201210157968.6 / CN
103001175, EP 2 813 856

Werbung