Herunterladen Inhalt Inhalt Diese Seite drucken

Mastervolt MASS 12/150 Betriebsanleitung Seite 19

Batterielader
Inhaltsverzeichnis

Werbung

MASTERVISION MODULAR SWITCHBOARDS
CAUTION
1. Lethal voltages exist on your vessel. Make sure all shore power, onboard
generating sources and batteries are disconnected before beginning
installation of your electrical panel.
2. AC modules will have lethal voltages on the bus bars and terminals. The
coating on these bars is for identification only and should not be relied on as a
insulator. Additional safety enclosures may be required in some installations.
3. Make sure all AC modules are bonded to the shipís AC ground bus. When
grouping modules together to form your panel, a single ground may be used.
Use a resistance meter to verify ground to all modules.
The standard remote panel
The standard remote panel is a useful power device for
remote control of the Mass an IVO smart Mastervolt
battery chargers. The standard remote control does indicate the
status of the charge control by six high power leds and control
the output current by setting the potential meter. The remote
control is easy to install by a plug-in standard twisted six pole
RJ45 telephone plug between the digital rs232 output of the
charger and the panel. The serial communication of the remote
control and the charger is based on rs232 technology.
The remote panel can be used as an interface for a custom
made panel or for a dual remote indicator.
The standard remote panel has a CSI (csi=charger
status interface) and a DC high/low alarm.
The two potential free change-over contacts indicate if the
charger is ON or in general failure. The DC alarm set
points can be adjusted in the charger by use of the
adjustment interface.
Specifications
Remote cable:
Connector
RJ45, 6 pole, male
Max length
6 meter, max
Type
reversed wire
External led drive:
Imax
5 mA
Umax
2,5V
External current control
R pot cc
0..1kOhm 0..100%
General CSI alarm
Max rating
1 Amp, 30 VDC
NC-on
When the charger is off or the
charger is in failure, the normally
closed contact is closed
C
Common
NO-on
When the charger is on and
no-failure is indicated the normally
open contact is closed
DC-high/low alarm (combined function with CSI)
Max rating
1 Amp, 30 VDC
NC-on
When there is no DC failure, the
normally closed contact is closed
C
Common
NO-on
When there is a DC failure the
normally open contact is closed
Connectors
0,75 mm
Appendix B
DC alarm
normally closed
normally open
common
CSI alarm
normally closed
normally open
common
CSI failure
Bat TC failure
Voltage sense failure
Sys. temp. failure
Short break indicator
DC alarm
2
www.Busse-Yachtshop.de
panel code
part number
SPECIFICATIONS
description:
type:
dimensions panel (wxh):
panel depth:
Charger Control
float
absorption
on - bulk charge
failure
external
current control
1 2 3 4 5 6
6 pole telephone jack
1 2 3 4 5 6
RJ 45
Battery temperature sensor out of range <20°C & >60°C
Voltage sense out of range >3 VDC
Charger is out of temperature range "overload" (>75--85 C)
Charger in reduced current mode (short break mode)
Uout <4..5VDC
Battery range out of range (with standard setting of charger)
DC low on
DC low off
DC high on
DC high off
Delay time
info@busse-yachtshop.de
C-3-RS
07-04-03040
remote standard charger control
for Mass & IVO smart chargers
120 x 65 mm
40 mm
current output
external LED failure
external LED bulk
external LED 20-40%
external LED absorption
external LED 60-80%
external LED float
charger
12V
24V
10.0
20.0
VDC
11.0
22.0
VDC
16.0
32.0
VDC
15.0
30.0
VDC
30
30
SEC
103

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis