English
I
6
G
or
Zaptec
Cable seal
Seal the unused cable entry using the blanking
plug supplied. Tighten strain relief nuts on blanking plug
and cable until secure.
Place the cable seal over the cable entry in order to seal it
properly. The cable seal must be pulled down towards the
junction box and then pushed all the way down, so that
the cone ends up in the correct position as shown below.
Visually check that the seal has a good sealing surface.
8
Test the installation
To test the installation after the cover has been screwed on,
you must use the female connection. If you test directly on
the back plate, the connections will be damaged.
(Webshop reference ZB10000zz).
NB: You must not insert test-
probes into the charging station
connector as it will be damaged
by this.
3
9
Protect the connections
Apply the adhesive sticker to protect the connections
if you are not installing the charging station directly after.
14
Good sealing surface
Poor sealing surface
4
leder kabel i tilfelle det installeres en transformator senere for
bedre ladeytelse. Da kan den nøytrale koblingen gjøres i sikringss-
kapet heller enn på hver enkelt ladestasjon, slik at det blir enklere å
gjøre fremtidige oppgraderinger.
7
Screw on the junction box cover
Screw on the junction box cover. The junction box screws
must be tightened to a torque of 0.7 Nm.
Use the correct cable seal for the cable. Check the
cable dimension and select an appropriate cable
7. For å teste installasjonen etter at lokket er skrudd på må du
bruke hunnkoblingen. Dersom du tester rett på bakplaten vil
seal. Small cable seal – cable dimension 10-16.
koblingene bli ødelagt.
Large cable seal – cable dimension 16-21.
230V
Dept.
Technical reference
Do not insert test probes, wires or anything
else into the quick-release connector on the
back plate. Voltage tests should be performed
directly on the terminal screws or using a female