3. Proper use

The machine is suitable for spraying solvent-bor-
ne and water-borne paint, varnish, primers, trans-
parent lacquer, vehicle basecoats and clearcoats,
interior wall paint, stains and wood preservatives.
Alkali and acidic substances, spray materials
containing particles, latex paint and non-drip/non-
splatter paint must not be sprayed.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data

4.1 TC-SY 600 S technical data
Mains voltage/frequency ........ 220-240 V ~ 50 Hz
Power rating ............................................. 600 W
Max. fl ow rate .....................................1000ml/min
Container ..................................................800 ml
Nozzle dia. .......................................2.5 / 3.0 mm
Max. viscosity .................................... 70 DIN-sec
Protection Class ............................................ II/
Ingress Protection ...................................... IP 23
Weight .......................................... approx. 2.6 kg
Hose length ................................................ 1.8 m
4.2 TC-SY 700 S technical data
Mains voltage/frequency ........ 220-240 V ~ 50 Hz
Power rating ............................................. 700 W
Max. fl ow rate .....................................1000ml/min
Container ................................................1000 ml
Nozzle dia. .......................................2.5 / 3.0 mm
Max. viscosity .................................... 70 DIN-sec
Protection Class ............................................ II/
Ingress Protection ...................................... IP 23
Weight .......................................... approx. 3.2 kg
Hose length ................................................ 3.5 m
Anl_TC_SY_600_700_SPK9.indb 23
GB
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN 50580.
L
sound pressure level ........................ 83 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level .......................... 94 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 50580.
Handle
Vibration emission value a
K uncertainty = 1.5 m/s
The specifi ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specifi ed value
in exceptional circumstances.
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful eff ect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
- 23 -
= 1.57 m/s
2
h
2
10.11.2020 14:20:51