6.5 Use of the function "Liquid"

EN
Use the "Liquid" function to vacuum and seal bags which are fi lled with liquids or moist
FR
goods. We recommend using a stand-up vacuum bag for liquids.
IT
1.
Place the device on a dry place.
2.
Unfold the bottom of the bag and place it in an
ES
upright position. The bag should only be fi lled to
maximum approx. 1/3 to allow it to be folded back-
NL
wards toward the vacuum chamber.
3.
Use the "Food" button to select the "Liquid" option
PT
for the sealing time. If you select "Liquid", then the
SE
"Soft" option will automatically be selected for the
vacuum intensity. It is not possible to select the
"Normal" option.
4.
Pres the "Vacuum & Seal / Cancel" button to start the vacuuming process.
5.
The corresponding LED lights up and turns off when the process is complete. The
"Progress" light indicates progress of the process.
PLEASE NOTE
If liquid gets sucked into the removable drip tray, then remove the tray from the device
and clean it. In addition to this, make sure that you also clean the inside of the device.
6.6 Use of the function „pulse" vacuum
Since the pressure of vacuum sealing is too great for some foods and they could be
crushed in the bag, you can use the „Pulse" function to regulate the duration and thus the
strength of the vacuum sealing process. So you can adjust the vacuum strength to the
consistency of your vacuum food and also seal soft foods (for example berry fruit) without
crushing them. The time and pressure regulation prevents delicate food from being crus-
hed. When packing some juicy foods, you can also use this function to prevent liquid from
being sucked in and drawn out.
1.
Place the device on a dry place.
2.
Open the device using the handle.
3.
Place the food to be preserved inside the bag.
4.
Make sure that the open end of the bag is inside the vacuum chamber.
5.
Close the lid and push down the handle.
6.
Press the „Pulse" button. As long as you keep the button pressed, air is extracted. Only
when you release the button, the process stops.
7.
Please hold the button pressed until the required vacuum has been reached.
8.
The LED of the „Seal" key fl ashes.
9.
Then press the button „Seal" and seal the bag.
PLEASE NOTE
If too much air has been extracted, you can wait a moment and the device will let air
into the bag again. You can repeat the process.