12.2 Technical data for PPB 30
External diameter
Wall sleeve
(max. length)
Wall thickness
Air filter inside/outside
Air volume/unit
in exhaust air mode
Degree of protection
Sound pressure level,
at distance of 1 m
conditions without
obstructions
(ventilation level 1 to 5)
Rated voltage/
power frequency
Volumetric flow
heat recovery mode
ventilation level 1 to 5
Volumetric flow
exhaust air mode
Power consumption
(ventilation level 1 to 5)
Degree of heat
provision
SPI
SEC value
Permissible ducting
lengths with wired
connection
Weight
slide-in module cpl.
DN 160
PP 45 RHK: 500 mm
PP 45 RHL 800 mm
320 - 790 mm
G3/G3
45 m³/h
IP X4
18 / 32 / 41 /
45 / 49 dB(A)
230 V
50/60 Hz
5 / 12 / 18 / 22 / 26 m³/h
45 m³/h
1.7 / 2.5 / 3.4 /
4.4 / 5.3 W
73,3 % (level 3)
0.19 W / (m³/h)
A (-39.41)
From star point
max. 25 m per
ventilation unit
3.6 kg
13 Dismantling
Ventilation units may only be dismantled by a
person with electrical training.
DANGER
!
Danger of electric shock.
Before removing the front cover, disconnect
the ventilation unit at all poles from the power
supply, secure against being accidentally
switched back on and position a visible
warning sign.
14 Environmentally responsible
disposal
The ventilation unit and the packaging contain
parts that can be recycled, and should not
end up in the domestic waste.
Dispose of the packaging material in an
environmentally-friendly way, in compliance
with the regulations valid in the country where
you are.
Dispose of the air filter and the unit (at the
end of its useful service life) in an environ-
mentally-friendly way, in compliance with the
regulations valid in the country where you are.
13 Dismantling | UK
59