Diaphragm valve type 514, 515, 517, 519
8

Troubleshooting

Malfunction
Leakage to the outside at flange connec-
tion
Leakage to the outside at union nut
Leakage between Valve body and housing
nut connection
Seat leakage/through hole leakage
Leakage at position indicator pin
Diaphragm valve does not close comple-
tely
Diaphragm valve does not open comple-
tely
Valve actuation sluggish
Pipe and/or diaphragm valve deform or
expand
Premature wear of the diaphragm valve
or individual parts
White discoloration on the housing nut
30
Possible Cause
Temperature change
Gasket defective
Loose connection of union nut and Valve
body
Gasket defective
Housing nut not tightened correctly
Diaphragm wear
Valve body defective
Diaphragm not correctly installed/
aligned
Diaphragm wear
Wear of the gaskets or diaphragms
Pressure in the piping system too high
Foreign bodies between diaphragm and
Valve body
Components defective
Diaphragm not correctly installed/
aligned
Wear of the spindle or gaskets
Pipe forces are too high
Materials are not sufficiently resistant
Medium is contaminated
Chemical damage
Operating Instructions
Troubleshooting
► Tighten connection and replace
gasket if necessary.
► Replace gasket.
► Tighten the connection hand-tight.
► Replace gasket.
► Tighten the housing nut.
► Replace diaphragm.
► Check Valve body for damage and
replace if necessary.
► Check that the diaphragm is
correctly installed.
► Replace diaphragm.
► Change spindle and piston gaskets.
► Replace diaphragm.
► Operate valve only within the
specified data.
► Remove foreign bodies and check
Valve body and diaphragm for
damage.
► Check Valve body and diaphragm for
damage and replace if necessary.
► Check that the diaphragm is
correctly installed.
► Replace gaskets and, if necessary,
functional parts.
► Improve support of the pipe.
► Select suitable materials, see GF
Planning Fundamentals Industry.
► Check/clean medium for contamina-
tion.
► Immediate diaphragm replacement
of all worn components under all
specified safety procedures.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

515517519

Inhaltsverzeichnis