Herunterladen Inhalt Inhalt Diese Seite drucken

Handicare 2000 SIMPLICITY Installationsanleitung Seite 49

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 122
Code:
Meaning:
o
Default Eeprom
Description:
The Eeprom has been reset to its default value
(Flash Failure).
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
Meaning:
r
No charge current
Description:
Activated.
Telephone fault finding action:
Check that power supply is switched on from mains
supply. If yes send engineer.
On site fault finding action:
Check power supply.
Code:
Meaning:
y
Software error
Description:
The main control board has a software fault.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
Meaning:
.8.
N/A
Lift is in "sleep mode" to
conserve battery power
Description:
Telephone fault finding action:
None.
On site fault finding action:
Press toggle or handset button to wake lift.
P
Description:
Powered swivel did not respond.
Telephone fault finding action:
NOT YET ACTIVE.
On site fault finding action:
NOT YET ACTIVE.
U
Description:
Faulty power supply.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace power supply.
Description:
N/A.
Telephone fault finding action:
Send engineer with a service exchange power pack.
On site fault finding action:
Replace power pack.
Note: If the display is showing
anything but the diagnostic codes
listed it requires resetting.
Drive the lift off the charge contacts.
Turn the main switch on the unit off
for 10 seconds and then back on.
HANDICARE 2000 SIMPLICITY / STYLE INSTALLATION MANUAL 49
Code:
Meaning:
P
PS no reply
Code:
Meaning:
U
No float indication V1.19
software and later only
Code:
Meaning:
N/A
Over current
Appendix 2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2000 style

Inhaltsverzeichnis