9.1 PIN code

The default PIN code for accessing the device via
the app is "1234" . If the PIN code is changed,
the app will ask you to enter the new PIN code
once before the device can be operated .
To change the PIN code, call up the menu
item
NetRemote PIN Setup
tem settings" under
menu will appear:
NetRemote PIN Setup
1234
0123456789
Turn the knob CONTROL SELECT to select the
digits and the three command buttons and press
the knob to confirm .
= delete the last digit entered
BKSP
= confirm PIN code
OK
= return to previous menu
CANCEL
If control via the network fails to work, please
check the following requirements:
– Make sure that the device has not been switched
off with the POWER switch .
– Make sure that the option
for
Keep network connected
made via the setup wizard or the corresponding
menu item in the menu "System settings") . This
way, the device will always maintain the connec-
tion to the network, even in standby mode .
– Make sure that the smartphone / tablet and the
device are connected to the same network .
– Make sure that the router allows communication
between wireless LAN devices in the network .
If not, activate the corresponding setting on the
router .
52
or
in the menu "Sys-
. The following
Network
BKSP
OK

CANCEL
has been selected
YES
(setting can be

10 Control via RS-232 Interface

Via the RS-232 interface, the device can be con-
trolled from a computer with a terminal program
designed for this purpose . Setting up the RS-232
control connection requires specific technical
knowledge .
Connect the 9-pole D-Sub jack on the rear panel
of the device to the RS-232 interface of the com-
puter (if there is no RS-232 interface on the
computer, use an adapter "USB to RS-232") .
A UART connection is used for communication
between the computer and the device . The fol-
lowing parameters apply:
Baud rate
Start bit
1
Stop bit
1
Control commands (hexadecimal code)
Function
Command
P1
07
P2
0A
P3
0B
P4
0E
P5
0F
P6
3A
P7
3B
P8
3C
P9
3D
P10
3E
Function
STANDBY
SHIFT
PRESET
SLEEP
MENU
INFO
ALARM
ENTER /
FM TUNER SCAN
station scan, upwards
MODE
Mode "Internet radio"
Mode "Music player"
Mode "DAB radio"
Mode "FM radio"
19200 Bd
Data bits
8
Parity
none
Function
Command
P1
02
P2
03
P3
04
P4
05
P5
06
P6
33
P7
34
P8
35
P9
36
P10
37
Command
01
15
17
18
19
1A
1B
1C
1D
3F
40
41
42