Alarm Functions

It will be possible to trigger an alarm via the internal
motion detector, via an alarm input for external sen-
sors (e. g. light barrier or motion detector), if a video
signal is lost or if the hard disk is full or missing.
Depending on the configuration of the recorder,
there are various responses to an alarm, e. g. start of
a recording, activation of the alarm output, acoustic
alarm signal, insertion of a message on the screen,
transmission of an e-mail with a photo of the object
triggering the alarm.

10.1 Alarm configuration

1) Activate the submenu
DEVICES/ DEVICE MANAGE-
MENT
(fig. 22) in the main menu (fig. 10).
2) Activate the submenu
ALARM
(fig. 37).
Submenu ALARM SETUP
3) In the line
I/O STATUS
input in the list field if it is to be evaluated and
define the contact type of the sensor connected:
OFF
the input will be ignored
NO
contact type NO (normally open)
NC
contact type NC (normally closed)
Note: To trigger an alarm via an alarm input, the
corresponding camera channel must be approved
for recording (submenu
line
CHANNEL
=
ON
,
chapter 8.1).
For DMR-188 only:
For setting the camera channels 5 – 8, click
Then click
PREV.
to return to the previous menu
page.
4) In the list field next to
HDD LOSS
is to be triggered (
ON
) or not (
disk is missing.
5) In the list field next to
alarm is to be triggered (
hard disk is full.
6) In the list field next to
VIDEO LOSS
alarm is to be triggered (
there is no video signal.
Note: To trigger an alarm in case of video signal
loss, the corresponding camera channel must be
approved for recording! (Submenu
SETUP
CHANNEL
ON,
, line
=
ALARM MANAGE
7) In the item
DURATION
, define the length of the video
sequence (
3OS,
1MIN,
recorded when an alarm has been triggered via
an alarm input or via the internal motion detector.
8) In the list field next to
OUTPUT
time of the relay (
1OS, 2OS, 4OS, 6OS
alarm output ALARM (24) after alarm triggering or
if response is not desired (
9) In the list field next to
BUZZER
of the acoustic alarm signal (
32
6OS
alarm signal is not desired (
10)To send a message by e-mail in case of alarm
and to activate this option, click the button
SETUP
11)To reset all settings of this submenu to the factory
settings, click the button
12)To store the settings, click the button
confirm the message inserted "
fully!
13)To exit the submenu, click the button
right mouse button or press the button MENU /
ESC (7) or MENU (32).

10.2 Notification by e-mail

/
ALARM SETUP
If the recorder is connected to a computer network
via the jack LAN (23) and this network is connected
to the Internet (
notification by e-mail to an address previously
defined will be possible. As an attachment, the
e-mail will contain an image file in JPG format show-
ing a snapshot from the video signal of the camera
channel triggering the alarm.
To configure the notification by e-mail:
1) After clicking the button
menu
EMAIL SETUP
, define for each alarm
Submenu EMAIL SETUP
RECORD
/
RECORD SETUP
,
Example: transmission via "Google Mail"
2) In the list field next to
cation function is to be activated (
NEXT
.
3) When the notification function has been acti-
vated, enter the parameters required for sending
e-mails:
, define if an alarm
OFF
) when the hard
SSL
SMTP PORT
SEND EMAIL
HDD SPACE
, define if an
ON
OFF
) or not (
) when the
SEND PW
RECV EMAIL
, define if an
ON
) or not (
OFF
) when
In chapter 6.2.3, a text input is described in detail.
In addition to the input possibilities for the camera
names listed there, special characters (fig. 39)
will also be available.
RECORD
/
RECORD
chapter 8.1)
in the list field next to
2MIN,
5MIN
) to be
4) To reset all settings of this submenu to the factory
settings, click the button
, define the closing
5) To store the settings, click the button
) at the
confirm the message inserted "
fully!
OFF
).
6) To exit the submenu, click the button
, define the duration
right mouse button or press the button MENU /
1OS, 2OS, 4OS,
ESC (7) or MENU (32).
) in case of alarm triggering or if an acoustic
OFF
).
(for details see chapter below).
DEFAULT
.
Saved success-
" by clicking the button
OK
.
chapter 14.1), in case of alarm,
EMAIL SETUP
ALARM
/
ALARM SETUP
(fig. 37), the submenu
will appear (fig. 38).
EMAIL
, define if the notifi-
ON
) or not (
encryption
ON
or
OFF
port number for transmission
address of sender
password for access to the mail
server for transmission
address of receiver
Set of special characters
DEFAULT
.
Saved success-
" by clicking the button
OK
.

10.3 Motion detection

To configure the internal motion detector:
1) Activate the submenu
EMAIL
MENT
(fig. 22) in the main menu (fig. 10).
2) Activate the submenu
(fig. 40).
APPLY
, then
EXIT
or the
Submenu MOTION DETECTION
3) In the line
STATUS
camera channel if a movement detected is to be
evaluated as an alarm (
Note: To trigger an alarm via motion detection, the
in the sub-
corresponding camera channel must be approved
for recording! (Submenu
line
CHANNEL
=
4) In the line
SENSITIVITY
sensitivity for motion detection (1 = low, 4 = high)
of each camera channel.
5) To define the coverage (
ton
SETUP
in the corresponding column. The
camera image will be displayed with a grid of
13 × 10 fields over it (fig. 41). The red fields will
mark the coverage for motion detection.
OFF
).
Motion detection grid
6) To change a field, click the field with the mouse
pointer or select a field with the buttons
(8),
(10) and
,
(29) on the remote control and confirm with
the button SEL / EDIT (9) or SEL (33). To change
large areas, keep the mouse button pressed and
move the mouse pointer over the area.
To exit the area definition, click the right
mouse button or press the button MENU / ESC (7)
or MENU (32).
7) For DMR-188 only:
For setting the camera channels 5 – 8, click
Then click
PREV
page.
8) To reset all settings of this submenu to the factory
settings, click the button
APPLY
, then
9) To store the settings, click the button
confirm the message inserted "
fully!
" by clicking the button
EXIT
or the
10)To exit the submenu, click the button
right mouse button or press the button MENU /
ESC (7) or MENU (32).
DEVICES/ DEVICE MANAGE-
MOTION
/
MOTION DETECTION
, define in the list field for each
ON
) or not (
OFF
).
RECORD
/
RECORD SETUP
,
ON,
chapter 8.1).
in the list field, set the
MD AREA
), click the but-
and
(13) on the recorder or
,
,
NEXT
.
. to return to the previous menu
DEFAULT
.
APPLY
, then
Saved success-
OK
.
EXIT
or the

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dmr-188Dmr-184

Inhaltsverzeichnis