14.2.2.1 Replay control

Similar to the description in chapter 9, it will be pos-
sible to control the replay of a video file in the lower
part of the window (fig. 58). The vertical box (green)
will indicate the current replay position within a video
file and can also be displaced with the mouse to
select a particular point of time. The horizontal bar
(blue) behind it will indicate the download process of
the file from the recorder. With large files, delays
may occur in operation while the file is still being
loaded.
View REPLAY, replay control
The explanation of the buttons:
PAUSE
to interrupt the replay,
indication: "PAUSE"
PLAY
to start or continue the replay
indication: "1x"
F.F.
to replay at 2-fold, 4-fold,
8-fold or 16-fold speed
(click repeatedly)
indications: "2x", "4x", "8x",
"16x"
SLOW
to replay in slow motion at
1
1
1
,
,
or
2
4
8
speed (click repeatedly)
indications: "-2x", "-4x",
"-8x", "-16x"
NEXT FRAME
to interrupt the replay and to
continue in frames
indication: "Step"
To adjust the volume of audio replay, use the "slid-
ing control" on the right.

14.2.2.2 Converting video files

The files recorded from the video recorder and the
video files recorded on the computer via the function
"RECORD" in the view "LIVE" (
will be compressed according to the standard H.264.
To replay them with programs not yet supporting this
standard, store the files in AVI video format.
For this purpose, files from the recorder must be
downloaded to the computer first by means of the
button "BACKUP" (fig. 57) and stored there.
For converting:
1) Click "264 TO AVI" (fig. 58). The window "Avi-
Convert" (fig. 59) will open.
Conversion to AVI format
2) In the line "SOURCEFILE", enter the path of the
file to be converted or click the button "..." and
search for the file. The files from the recorder will
be in the directory "Backup", the files recorded on
the computer in the directory "Record" in the path
defined under "SETUP / SETTING", "FILE SAVE
PATH" (
chapter 14.2.3.5).
3) In the line "DESTINATIONFILE", enter the path
and the name of the target file (with the extension
.AVI) or click the button "...", search for the path
and enter the file name.
4) Click "Convert" to start converting. After success-
ful conversion, the message "Conversion fin-
ished!" will appear.
5) For further conversions, repeat steps 2 – 4. Then
close the window "AviConvert".

14.2.3. View "SETUP"

Via the view "SETUP", it will be possible to retrieve
information concerning the recorder, to change set-
tings of the recorder and to make settings for remote
access.

14.2.3.1 SETUP/ RECORD

View SETUP
The settings made in the view "SETUP / RECORD"
(fig. 60) will affect the submenu "
the recorder (
The following definitions will apply:
for "RESOLUTION" (not for DMR-188)
1
of the normal
16
HIGHEST =
HIGH
NORMAL =
for "QUALITY"
BEST
FINE
NORMAL =
for "AUDIO"
ON
OFF
for "REC.MODE"
chapter 14.2.1.2)
TIMER RECORD =
POWER UP
For DMR-188 only:
For setting the camera channels 5 – 8, click the
button "NEXT". Then click "PREVIOUS" to return
to the previous view.
If "TIMER RECORD" has been selected, the record-
ing schedule (fig. 61) will open via the button
"SCHEDULE".
View SETUP / RECORD / SCHEDULE
As described in chapter 8.2.3, it will be possible to
define the recording schedule for the camera chan-
nels here.
The following definitions will apply: "NORMAL" =
GENERAL
and "NO" =
If you click "APPLY", the recorder will accept the
changes; if you click "EXIT", the window will be
closed. After successful transmission, the message
"Configure success!" will appear.
/
RECORD
RECORD SETUP
chapter 8.1).
D1
(in the recorder menu)
=
HD1
CIF
=
BEST
GOOD
=
NORMAL
=
ENABLE
=
DISABLE
TIME SCHEDULE RECORD
=
ALWAYS
NO RECORD
.
14.2.3.2 SETUP /ALARM
View SETUP/ALARM
The settings made in the view "SETUP/ALARM"
(fig. 62) will affect the submenu "
MOTION DETECTION
(
chapter 10.1) and "
ter 10.3) of the recorder. The following definitions will
" in
apply: "I / O ALARM" =
I/O STATUS
DURATION
menu, "POST REC" =
= "0" =
OFF
.
For "MOTION DETECT" under "SENSITIVITY":
LOW
=
1
(in the recorder menu)
NORMAL =
2
HIGH
=
3
HIGHEST =
4
In the window inserted via the button "SETUP", the
coverage of motion detection for each channel will
be defined, like on the recorder, by clicking the grid
fields (red marking) [the outermost fields are not part
of it]. However, the camera image will not be visible
(fig. 63).
View SETUP/ALARM / MOTION
Click "CLEAR" to reset all fields, "CONFIRM" to
accept the changes made, "CANCEL" to abort them.
For DMR-188 only:
For setting the camera channels 5 – 8, click the
button "NEXT". Then click "PREVIOUS" to return
to the previous view.
Via the button "DEFAULT", the factory settings will
be displayed. If the button "APPLY" is clicked, any
changes made in the view "SETUP/ALARM" will be
transmitted to the recorder. After successful trans-
mission, the message "Configure success!" will
appear.
GB
ALARM SETUP
"
" (
chap-
in the recorder
and for "OUTPUT"