Endress+Hauser iTHERM CompactLine TM311 Betriebsanleitung Seite 19

Kompaktthermometer mit io-link
Vorschau ausblenden Andere Handbücher für iTHERM CompactLine TM311:
Inhaltsverzeichnis

Werbung

iTHERM CompactLine TM311
Bezeichnung
Index
(dez)
Switch point value
2051
Switchback point value
2052
Switch delay
2053
Switchback delay
2054
4 mA value
8218
20 mA value
8219
Current trimming 4mA
8213
Current trimming 20mA
8212
Failure mode
8234
Failure current
8232
Operating time
6148
Alarm delay
6147
Device status
36
Detailed device status
37
Actual diagnostic 1
6184
Actual diagnostic 2
6186
Actual diagnostic 3
6188
Previous diagnostics 1
6214
Timestamp 1
6204
Previous diagnostics 2
6216
Timestamp 2
6205
Previous diagnostics 3
6218
Timestamp 3
6206
Previous diagnostics 4
6220
Timestamp 4
6207
Previous diagnostics 5
6222
Timestamp 5
6208
Current output simulation
8210
Current output simulation
8211
value
Sensor simulation
3109
Sensor simulation value
3104
Switch output simulation
2056
Sensor min value
3081
Sensor max value
3080
Lower boundary operating
3132
time sensor
Endress+Hauser
Index (hex) Größe
Datentyp
(Byte)
0x0803
4
Float
0x0804
4
Float
0x0805
1
UInteger8
0x0806
1
UInteger8
0x201A
4
Float
0x201B
4
Float
0x2015
4
Float
0x2014
4
Float
0x202A
1
UInteger8
0x2028
4
Float
0x1804
4
UInteger32 r/–
0x1803
1
UInteger8
0x0024
1
UInteger8
0x0025
36
OctetString r/–
0x1828
2
UInteger16 r/–
0x182A
2
UInteger16 r/–
0x182C
2
UInteger16 r/–
0x1846
2
UInteger16 r/–
0x183C
4
UInteger32 r/–
0x1848
2
UInteger16 r/–
0x183D
4
UInteger32 r/–
0x184A
2
UInteger16 r/–
0x183E
4
UInteger32 r/–
0x184C
2
UInteger16 r/–
0x183F
4
UInteger32 r/–
0x184E
2
UInteger16 r/–
0x1840
4
UInteger32 r/-
0x2012
2
UInteger16 r/w
0x2013
4
Float
0x0C25
1
UInteger8
0x0C20
4
Float
0x0808
2
UInteger16 r/w
0x0C09
4
Float
0x0C08
4
Float
0x0C3C
4
UInteger32 r/–
Zugriff Defaultwert
Wertebereich
r/w
100 °C (212 °F)
-1E+20 ... 1E+20
r/w
90 °C (194 °F)
-1E+20 ... 1E+20
r/w
0 s
0 ... 99 s
r/w
0 s
0 ... 99 s
r/w
0 °C (32 °F)
–50 000 ... 50 000 °C
r/w
150 °C
–50 000 ... 50 000 °C
r/w
4,00 mA
3,85 ... 4,15 mA
r/w
20,00 mA
19,85 ... 20,15 mA
r/w
0 = Low alarm
0 = Low alarm
2 = High alarm
r/w
22,5 mA
21,5 ... 23 mA
r/w
2 s
1 ... 5 s
r/–
0 = Device is OK
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
Gemäß IO-Link-Spezifikation
33004 = Off
33004 = Off
33005 = On
r/w
3,58 mA
3,58 ... 23 mA
r/w
0 = Off
0 = Off
1 = On
r/w
0 °C (32 °F)
-1E+20 ... 1E+20 °C
0 = Disabled
0 = Disabled
33004 = Off
33006 = On
r/–
r/–
Systemintegration
Data
Storage
Ja
Ja
Ja
Ja
Ja
Ja
Ja
Ja
Ja
Ja
Ja
Ja
19