Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Speci Cations - x-sense Link XS01-WR Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Link XS01-WR:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NOTES
1. You can silence all interconnected units by pressing the test/silence
button on one of the units. If one unit is still alarming, it is the initiating
unit (the unit that detected danger); to silence all interlinked units, you
must also press the test/silence button on the initiating unit.
2. While interconnected, the initiating unit cannot be triggered again
during the 9-minute silence duration. However, all other interconnected
units can be triggered again if they detect danger during the silence
mode.

Technical Speci cations

Power Supply
Replaceable 3 V CR123A lithium battery
Operating Life
10 years
Battery Life
5 years
Sensor Type
Photoelectric
Safety Standard
EN 14604:2005+AC:2008
Standby Current
< 15 uA (avg.)
Alarm Current
< 150 mA (avg.)
Coverage Area
215-430 ft
2
2
(20-40 m
)
20
Best Operating Ambient
40–100°F (4.4–37.8°C)
Temperature
Operating Relative Humidity ≤ 85% (non-condensing)
Alarm Loudness
≥ 85 dB at 10 ft (3 m) @ 3.2 ± 0.3 kHz pulsing
alarm
Silence Duration
About 9 minutes
Operating Frequency
868 MHz
Maximum Number of
24 wireless units (only compatible with
Interconnected Units
X-Sense wireless alarms)
Transmission Range
Over 820 ft (250 m) in open air
NOTES
1. Battery life is calculated on the current ratings in the standby mode with weekly
testings. If its operation mode changes to an alarming condition, the battery life
will be decreased accordingly.
2. The smoke alarm functions between 40 and 100°F (4.4 and 37.8°C). Prolonged
exposure to temperatures outside of this range can reduce battery life and aff ect
accuracy. We do not recommend operating the device outside of this range.