Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Alternative Electrical Connection - clage DEX Next L Gebrauchs- Und Montageanleitung

E-komfortdurchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
DEX Next L

6. Electrical connection

EN
A
Electrical connection
Note: If necessary, the connecting terminal can be displaced to the upper part of the
appliance. If you want to do so, please follow the instructions in the next chapter.
Check that the power supply is switched off prior to electrical connection!
1. Dismantle approximately 6 cm off the connecting cable above the wall outlet. With
the smaller opening ahead, slide the water splash protection sleeve over the con-
necting cable so that the sleeve is flush with the wall. This prevents any leaking
water from coming into contact with the electrical leads. It must not become dam-
aged! The protection sleeve must be used!
2. Strip the individual wires and plug them in the connecting terminals according to
the wiring diagram. The appliance must be earthed.
3. Pull the protective sleeve so far over the connecting cables and shape the connect-
ing cables in such a way that the sleeve fits perfectly in the recess of the intermedi-
ate panel without mechanical tension and fix it with the sleeve fixing (A).
4. Connect the control panel cable to the control panel in the hood, place the hood on
the appliance and fix it with the hood screw.
Note: The control panel cable must not be pinched or squeezed.

Alternative electrical connection

Check that the power supply is switched off prior to electrical connection!
1. Open the prepared breaking point (S) in the upper part of the appliance by pressing
with a blunt implement (e.g. srewdriver). For surface-mounted connection cable
additional open the breakout at the right side of the bottom part.
2. Slit the grommet of the accessory set to match the cable size. The opening in the
grommet should be slightly smaller than the cross-section of the cable in order to
ensure optimum protection against water. Fit the grommet into the opening. The
protection grommet must be used!
S
3. Strip the connection cable so that the sheath extends through the grommet into
the appliance. Hold the prepared appliance so that you can route the cable into the
grommet with the other hand.
4. Place the appliance on the wall bracket so that the threaded rod of the wall bracket
fits in the corresponding hole of the appliance.
5. Unscrew the fastening screw of the connecting terminal. Displace the connecting
terminal to the upper foot. Affix the connecting terminal again.
6. Strip the individual wires and plug them in the connecting terminals according to
the wiring diagram. The appliance must be earthed.
7. Connect the control panel cable to the control panel in the hood, place the hood on
the appliance and fix it with the hood screw.
Note: The control panel cable must not be pinched or squeezed.
Note: To ensure IP25 protection class, please don´t remove the bottom water splash
protection sleeve.
34