• Take down the control panel's front panel and correctly connect the cable between the
control panel and the electronic control.
• Clean the run-off pipe and valve blockages (take down the outside cover of the unit for
access).
• Check the unit's silicone seal and repair any possible leakage points with more silicone.
• Seal the cable output in the blower and evaporator cabin cover (remove the unit's
outside cover for access).
• Verify the load by checking the pressure; if it is below 0.5 bars or above 5.0 bars with the
unit running, restore the load and vacuum deair the circuit for at least 30 minutes, then
introduce 150 g of R134a gas (the unit has 150 g in each circuit).
• Clean the condenser with pressurised air.
• Connect or replace the condenser fan.
• Check the pressure; if it is below 0.5 bars with the unit running, clean the circuit or
replace the obstructed components (possibly the continuous flow capillary pipe).