SLIMFIT
• Repair possible obstruction of the condenser fan; if the error persists, replace the
condenser fan (to access the condenser fan remove the unit's outer cover).
• Replace 7.5A fuse. To access the fuses of the condenser fan, remove the control
panel's access cover fitted on the internal air distribution panel.
!
(If the error persists, contact the Authorised Technical Service).
• Repair possible obstruction of the centrifugal blower; if the error persists, replace the
centrifugal blower (to access the centrifugal blower, remove the unit's outer cover and
the evaporator cover).
• Replace 7.5A fuse. To access the fuses of the centrifugal blower remove the control
panel's access cover fitted on the internal air distribution panel.
!
(If the error persists, contact the Authorised Technical Service).
• Replace compressor 1.
• Correctly connect the module of compressor 1 or replace (to access the modules and
the compressors, remove the unit's external cover). Note: the references for each
module are different; check that it is replaced using the correct reference.
!
(If the error persists, contact the Authorised Technical Service).
Solution
21