Commissioning
Place the wetness control paper in the installation space of the EFOY fuel
cartridges.
Insert a new, full, sealed original EFOY fuel cartridge. Make sure that the EFOY
fuel cartridge is not wet. Wipe it dry if necessary.
After one minute, check the wetness control paper for wetness. If the wetness
control paper is wet, check your EFOY fuel cartridge for damage and replace it
with another EFOY fuel cartridge if necessary.
3
The M28 fuel cartridge can only be
connected via the additional M28
adapter (2). Screw the two fuel
cartridge connections of the EFOY
Fuel Manager FM2 (1) onto one M28
adapter (2) each.
Screw both M28 adapters (2) onto
one M28 fuel cartridge (3) each.