Diaphragm pump N952KTE-W N952KT.29E-W
Pump start pa-
rameter: LOCAL
Translation of Original Operating and Installation Instruction, KNF 339866-336533
02/23
Fig.5: Analog speed setpoint setting, Pump start: TOGGLE
The pump ignores the "Remote ON/OFF" signal. The pump
can be stopped by allowing the analog control voltage to fall
below its minimum value.
NOTICE! The optional "Remote RESET" function is dis-
abled for this setting.

7.6 Error management

1
Status bits
0
1
4
5
7
9
13
14
15
1
Tab.17:
bit- 2,3,6,8,10,11 and 12 not used
Function ei-bit
RUN
Active direction of
drive rotation
Speed control ON
Actuation type
Defined direction of
drive rotation
Emergency off
Error: blocked rotor on=1; off=0
Error: overcurrent
Error: overtempera-
ture
Operation
on=1; off=0
CCW=1; CW=0
on=1; off=0
Digital=1; Analog=0
CCW=1; CW=0
on=1; off=0
on=1; off=0
on=1; off=0