Herunterladen Inhalt Inhalt Diese Seite drucken

Vortice VORT PROMETEO PLUS HR 400 MP Betriebsanleitung Seite 17

Vorschau ausblenden Andere Handbücher für VORT PROMETEO PLUS HR 400 MP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

ENGLISH
BUILDING REGULATIONS DOCUMENT F1 2006
SYSTEM 4
CONTINUOUS MECHANICAL SUPPLY & EXTRACT
VENTILATION WITH HEAT RECOVERY
A continuous balanced mechanical central supply and extract system to
be positioned in loft or cupboard space. An integral heat exchanger
recovers a large percentage of heat energy that would have otherwise
been lost. In employing this type of system, there is no need to install
background ventilators in the dwelling.
CONTINUOUS SUPPLY AND EXTRACT
1 Determine the whole building ventilation rate from
Allow for in ltration by subtracting
- for multi storey dwellings: 0.04 x gross internal volume of dwelling
3
heated space (m
)
- for single storey dwellings: 0.06 x gross internal volume of dwelling
3
heated space (m
)
2 Calculate the whole dwelling extract rate at
adding the individual room rates for
3 The required air ow rates as as follows:
Maximum Extract Rate (boost)
The Minimum individual room extract rates sholuld be at least those
given in Table 1.1A for minimum high rate
Minimum air supply rate should be at least the whole building
ventilation rate in 1 above.
4 No Background ventilators are required with System 4
Table 1.1 A
Room
Kitchen
Utility room
Bathroom
Sanitary Accomodation
Table 1.1 B
Whole building ventilation rate (l/s)
In addition, the minimum ventilation rate should not be less than 0.3 l/s per m
for a two-storey building, add the ground and rst oor areas).
This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the
default value. If a greater level of occupance is expected, then add 4 l/s per occupant.
Table 1.1B
maximum operation
'minimum high rate'
is the greater step of 1 and 2 above.
Minimum intermittent extract rate
30 l/s (adjacent to hob);
or 60 l/s elsewhere
30 l/s
15 l/s
6 l/s
13
Minimum value in any dwelling of 0,3 l/s per m
by
from Table 1.1A
Continuous rate
Minimum high rate
13 l/s
8 l/s
8 l/s
Number of bedrooms in dwelling
1
2
3
17
21
2
internal oor area (this includes each oor, e.g.
HEAT RECOVERY
UNIT
BATHROOM
KITCHEN
Minimum low rate
Total extract rate
must be at least
the whole building
ventilation rate in
Table 1.1B
4
5
25
29
oor area
2
BEDROOM
LIVING
ROOM

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis