Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting And Load Application; Mounting Hints For Single Point Load Cells Pw18C3; Mounting Hints For Single Point Load Cells Pw18C3/H - HBM PW18C3 Serie Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PW18C3... Single point load cells
1

Mounting and Load application

Load must not be applied to the side where the cable connection is located,
as this would cause a force shunt.

1.1 Mounting hints for single point load cells PW18C3

Mounting of PW18C3 at load introduction:
4 x M6; strength class 10.9;
tightening torque 14 N⋅m. Recommended
flatness 0.1 mm of mounted area
)
*
If the load cell is mounted on a base plate with a flatness of <0,1
mm the safe load limit in loading direction increases to 1000 %

1.2 Mounting hints for single point load cells PW18C3/H...

Mounting of PW18C3/H1 at load introduction: 2xM6;
strength class 10.9; tightening torque 14 N⋅m
Mounting of PW18C3/H1:
4xM8 DIN 912; strength class
10.9; tightening torque 25 N⋅m
The threaded holes in the base
plate of the PW18C3/H2 are
intended for pressure
compensation (see
dimensions, chapter 4.2, 3 x
lock screw and 3 x precision
O−ring included).
A2445-1.0 en/de/fr
Load introduction
(customer contruction)
Mounting of PW18i with base plate:
4 x M6 DIN 912; strength class 10.9; tightening
torque 10 N⋅m; max. length of engagement 7 mm
Loading direction
Center of mounting plate
Notch for overload protection
PW18C3
in tension direction
recommended flatness: 0.1
Alternative load introduction
Loading direction
Center of mounting plate
PW18C3/H...
Recommended flatness: 0.1
7
Mounting plate
)
Base plate *
Mounting plate
HBM

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pw18c3Pw18c3/h1Pw18c3/h2

Inhaltsverzeichnis