Herunterladen Inhalt Inhalt Diese Seite drucken

Regulation Of The Flame Size; Device Shutdown - Planika Kl21 Rio Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für KL21 Rio:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
While keeping the knob still pressed start the flame by pressing the ignition button (3).
A spark will appear which ignites the main burner on the minimum flame height. If the flame did not ignite
repeat this process 2-3 times. This will be required especially when you have replaced and installed a new LPG
gas cylinder.
When the flame is ignited keep holding the knob for around 5 seconds until the thermo-couple, which will
keep the main valve in an open position, warms up.
You may now release the knob. If however the flame is extinguished repeat the process once again until a
stable flame is achieved.
WARNING!!!
After 2-3 unsuccessful attempts terminate and check the connections. Try again in 10 minutes. If the
installed gas bottle is new or the fireplace has not been used for a longer pe Riod the first thing that needs to be done
is to release air from the gas linkage. In this case conducting a few attempts will be needed until the flame is ignited.

4.3 Regulation of the flame size

When the flame is burning the desired height of the flame may be adjusted and regulated by turning the knob
clockwise or counter-clockwise.
To achieve a higher flame turn the know clockwise to "Hi" position. To achieve a lower flame turn the knob
counter- clockwise to "Lo" position (Fig. 9).

4.4 Device shutdown

To turn off the device, simultaneously press and turn the knob all the way clockwise. The gas supply will be
cut and the flame on burner will be turned off.
Additionally, close also the valve on the gas cylinder.
Fig. 8
– Ignition sequence
Fig. 9
– Flame regulation
Fig. 10
– Turning the device off
12
Inhaltsverzeichnis
loading

Inhaltsverzeichnis