WARNING
The solar modules are not designed for concentrated irradiation. Bundling or
concentrating solar irradiation through lenses or mirrors is therefore not permit-
ted and can damage the solar modules.
Solarwatt solar modules fulfill all the requirements of the extended test standard IEC
61215. The test load for the mechanical load test was increased by the factor of 1.5. The
local regulations or the standard EUROCODE 1 (EN 1991-1) should be used for the calcu-
lation of the snow loads on the module. It is important to note that these standards are
designed for impact on structures and do not explicitly take into account the installation
of solar modules.
NOTE
The solar module heats up during operation. Ensure that there is sufficient rear
ventilation to avoid reductions in yield. Also ensure that no flammable gases
can escape or accumulate close by.
In regions with particularly high snowfall, the pressure load calculated in accordance with
the standard based on local snow load information may be significantly exceeded due
to snow overhang or build-up on the solar modules, which could result in above-average
stress on the bottom frame edge.
24
Subject to change | © 2022 Solarwatt GmbH