Insert the RJ45 connector to the socket as shown in figure below.

4 - COMMISSIONING

You must connect your PC to the charging station to use functions and make configurations
below:
Login & Change password
OCPP settings
Cellular, Ethernet and Wi-Fi interfaces settings
Standalone mode settings
Download OCPP logs
Download HMI logs

4.1 CONNECT PC TO THE SAME NETWORK WITH HMI BOARD

In order to access Web Config UI, first you need to connect your PC and EV charger to the same
ethernet switch or connect EV charger to your PC directly.
Power-on the charging station. Default IP address of HMI board is 192.168.0.10. For this reason,
you need to give static IP to your PC in the same network with HMI board.
You should assign static IP address to your PC in 192.168.0.0/254 network which means that IP
address should be in a range of between 192.168.0.1 and 192.168.0.254 .
IG v7.3.0 2021
Table-15
Figure.29
© 2021 Vestel - All rights reserved
CN13
English - 36