2.7 - LOAD SHEDDING

This charging station supports load shedding functionality which provides immediate charging
current reduction in case of limited supply. Load shedding triggering signal is a dry contact
signal which must be provided externally.
When load shedding is activated, charging current reduces down to 8A. When load shedding is
deactivated, charging continues with maximum available current.
You can connect potential free load shedding signal as shown in below. See figure-21 ,table-14
and table-15.
Load Shedding Input State
IG v7.3.0 2021
Cable Terminal
3
4
Opened Contact
Closed Contact
© 2021 Vestel - All rights reserved
8
6 7
5
4
3
2
Figure-21
Input
Load Shedding Input +
Load shedding Input –
Table-14
Charge at max. available current
Charge at min. current (8A)
Table-15
1
3
Behaviour