Herunterladen Inhalt Inhalt Diese Seite drucken

Fuel EC 600 Benutzerhandbuch Seite 42

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

calculate the maximum pulse frequency by the input of your age and a percentage. The formula is:
x% (e.g. 50%,60%,70%,80% or 90%) x (220 – your age). TARGET HRC allows the direct input of the
maximum pulse frequency. After starting the programme, the resistance level will be controlled
automatically constantly during exercise and cannot be adjusted manually.
You may now adjust a target time for your workout. Press START to begin the workout. Press
INCLINE - / + to adjust the incline level. Press STOP to pause the workout and STOP again to
return to standby mode. If a target value is set for TIME, the machine will stop automatically if the
value has been counted down to 0. Press STOP to leave this mode and return to standby mode.
If there is no pulse signal received during workout, the console will show "CHECK PULSE" and after
1 minute it will switch to standby mode. If the current pulse is over target pulse, the console will beep
as a warning signal. If the actual pulse is more than 30 seconds over the target pulse, the device will
automatically stop.
User Mode
In this mode you can exercise according to your own programmed profiles. You can preset each
segment load in the profile (totally 20 segments) with the LEVEL - / + and ENTER buttons. After that,
you need to preset each segment's incline with the LEVEL - / + and ENTER buttons. After you have
finished your input, press and hold ENTER button to enter TIME presetting. Set your desired target
time and press START to begin the workout.
Press LEVEL - / + to adjust the resistance and INCLINE - / + to adjust the incline level. Press STOP
to pause the workout and STOP again to return to standby mode. If a target value is set for TIME,
the machine will stop automatically if the value has been counted down to 0. Press STOP to leave
this mode and return to standby mode.
Incline calibration
In standby mode, press ENTER and INCLINE + for 2 seconds to enter
the auto-calibration mode.
Factory setting mode
In standby mode, press ENTER and LEVEL + for 2 seconds to enter the factory setting mode.
These settings should only be amended after checking with the customer service. You may adjust
different system settings with the LEVEL - / + and ENTER buttons:
1. UNIT (KM/ML) - adjust to english or metric unit
2. BRIGHT(0~15) - adjust backlight brightness
3. SPECIAL(YES/NO) - set motor to special drive action
4. MAX LOAD(16-20-24-32) - set the maximum resistance value
5. UX DATA(ON/OFF) - 4 sets of user options
6. WHEEL(10~99) - Wheel setting
7. INCLINE LOAD(1~20) - set the maximum incline value
When the last option is set, the values will be stored and the device will be restarted. You may also
press STOP to exit.
42

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis