Technical data

7 TECHNICAL DATA
Technical features (MONOSplit)
Unit
Refrigerant piping
Liquid line
Gas line
Max equivalent length
Max. height difference outdoor unit / indoor unit
Refrigerant pre-charge
GWP
Tons of equivalent CO
2
Additional refrigerant charge
Unit
Electrical connections
Mains power supply (outdoor unit)
Outdoor unit --> indoor
unit connection
Power consumption (outdoor unit + indoor unit)
Cooling
Rated power input
Heating
Cooling
Rated current input
Heating
NOTE:
– at max. pipe length, the yield is approximately 90%
– with a height difference >5m it is advisable to insert a siphon.
n° cables / cross section
Signal
n° cables / cross section
Power supply
n° cables / cross section
Nominal (Min~Max)
Nominal (Min~Max)
Nominal (Min~Max)
Nominal (Min~Max)
27M
inch
Ø 1/4"
mm
Ø 6.35
inch
Ø 3/8"
mm
Ø 9.52
m
25
m
±10
kg/m
0.70 / 5
tco
675
2
t
0.47
t
g/m
12
27M
V / Hz / p
2 x 1.5mm
2 x 1.5mm
2
2 x 1.5mm
+ G
2
27M
W 600 (100~1.260) 900 (130~1.650)
W 623 (110~1.320)
A
2.6 (0.4~5.5)
A
2.7 (0.4~5.7)
35M
Ø 1/4"
Ø 6.35
Ø 3/8"
Ø 9.52
25
±10
0.70 / 5
675
0.47
12
35M
230 / 50 / 1
+ G
2
2 x 1.5mm
2
2 x 1.5mm
+ G
2
35M
950 (120~1.500)
3.91 (0.6~7.2)
4.13 (0.5~6.5)
29