Herunterladen Inhalt Inhalt Diese Seite drucken

EHEIM pHcontrol+ 6062 Bedienungsanleitung Seite 26

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
Installing the magnetic valve
DANGER! Suffocation and freezing.
Escaping CO
▶ Close the screw-on valve of the CO
into the CO
manometer (system pressure) must be at 0.
1. Sever the hose approx. 10 – 20 cm past the pressure reducer.
2. Connect the hose securing nuts ⑧ to the hose ends (⌦G).
Note the flow direction! The flow direction is indicated by an arrow on the magnetic
valve.
3. Connect the hose ends to the connecting pieces of the magnetic valve.
4. Secure both hose ends with the hose securing nuts.
5. Insert the plug of the magnetic valve into the corresponding connector of the pH
controller (⌦H).
Installing the check valve
CAUTION! Material damage.
▶ In order to prevent water from entering the cylinder, pressure reducer or the
magnetic valve, a suitable check valve must be installed between the CO
and CO
1. Sever the hose approx. 10 – 20 cm past the magnetic valve.
2. Connect both hose ends to the check valve ④ (⌦A).
Note the flow direction! The flow direction is indicated by an arrow on the check
valve.
Checking the tightness
1. Carefully open the screw-on valve of the CO
2. Set the system pressure to approx. 1.8 bar.
3. Check the tightness (hissing sound) of the CO
may lead to suffocation and freezing.
2
system. The CO
2
diffusor.
2
cylinder before integrating the magnetic valve
2
system must be depressurised! The indicator of the
2
cylinder.
2
system's hose connections.
2
26
cylinder
2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis