Programming via Touch module
1
To access the Settings menu:
1. Press the lock-release button
2. Press
3. Enter the supercode (default: 778899)
NOTE: to guarantee security, we recommend changing the supercode.
LOCK-RELEASE
Antonio
Rossi
LOCK-RELEASE
LOCK-RELEASE
Hans
Schneider
Lisa
Parker
Mik
Parker
Marco
Bianchi
Lisa
Schneider
SELECT LANGUAGE
Used to set the desired language
LAYOUT TYPE
Used to select the display type for the Touch module screen
• Name directory: show call buttons
• Direct call: show a keyboard used to call the user directly when the call address is
known
• Call with Name Search: display allowing manual searching for user names
• Dual button direct.: show dual call buttons
SYSTEM TYPE
Used to select the call type:
• Standard (Simplebus): in this mode, the user is identified by a name field and a call
address field no longer than 3 digits (between 1 and 240).
Example: Name = John Smith | Call address = 2
• Indirect call: in this mode the user is identified by a name field, a call address field
and an indirect call code field no longer than 6 characters.
Example: Name = John Smith | Call address = 2 | Indirect call code = 100
• Simplekey synchronised: in this mode the user is identified as described in standard
mode and the user directory is synchronised via the Simplekey module art. SK9020,
• Simplebus Top: in this mode, the user is identified by a name field, a Simplebus Top
address field no longer than 3 digits (between 1 and 500) and a call address field of 3
digits (between 1 and 240).
Example: Name = John Smith | Simplebus Top address = 25 | Call address = 015
• SBC TOP indirect call: in this mode, the user is identified by a name field, a
Simplebus Top address field no longer than 3 digits (between 1 and 500), a call
address field of 3 digits (between 1 and 240) and an indirect code no longer than 6
characters.
Example: Name = John Smith | Simplebus Top address = 25 | Call address = 015
Indirect call code = 100
• Simplekey synchronised Simplebus Top: in this mode the user is identified as
described in Simplebus Top mode and the user directory is synchronised via the
Simplekey module art. SK9020.
MANAGE USERS
Used to: add a user to the directory, edit/delete a user, delete the directory
Add user
f
For each contact, enter:
name*
second name
description
call address*
Simplebus Top address* (Simplebus Top systems only)
indirect call code* (only with indirect call type)
add access code: enter the access code for the user you are configuring
add RFID key: enter the RFID key code or pass it in front of the reader
visible: make the button you are programming visible or not (default: visible)
*
compulsory field (ONLY if the user is set as "Visible")
Once configuration is complete, press
Edit user
f
Press
to edit the information for that contact
Press
to delete the desired user
f
Once configuration is complete, press
Delete directory
Press "Delete directory" to remove all saved contacts
f
22
1
and confirm you wish to save.
and confirm you wish to save.
1
2
3
4
5
6
7
8
9
0
2
NAME DIRECTORY
MANAGE SUPERCODE
Used to edit the supercode (default 778899)
NOTE: the code must consist of at least 4 and no more than 6 characters
Once configuration is complete, press
KEYBOARD
Used to customise the keyboard
Set the keypad type by selecting one of the available options: Large buttons,
f
QWERTY, AZERTY
f
Set the keyboard format by selecting one of the following: Lower case, Upper case
RFID READER
Used to manage the RFID reader on the Touch module
• Enable: enables RFID reader operation in standard mode
» the
symbol turns red when the reader is enabled
» the
symbol flashes in green when an authorised RFID key is read
» the
symbol flashes in red when an unauthorised RFID key is read
• Enable- RS485: enables operation in conjunction with access control unit art.
SK9020.
» the
symbol turns red when the control unit is connected
» the
symbol flashes in green when an authorised RFID key is read
» the
symbol flashes in red when an unauthorised RFID key is read
For connection diagrams, please refer to the corresponding technical manual.
• Enab.-Wiegand: enables operation in conjunction with access control units which
utilise Wiegand protocol. The maximum connection cable distance is 150 metres
(UTP cable, CAT.5)
• Disable: disables reader operation
DISPLAY
Used to customise the maximum and minimum screen brightness
DATE AND TIME
Used to set the device date and time
NOTE: the date and time are only visible if enabled via ViP Manager
BLUETOOTH
Used to connect the Touch module to a computer (see page 23).
RESET
Used to restore the factory-set information
» At the end of the procedure the Touch module restarts
BACKUP/RESTORE
Used to force* backup of the device configurations for an up-to-date backup, and so that
the configurations can be restored by loading an existing backup.
*The micro-SD card provided can be used to save all the settings and logs for Touch
module art. 3455U. This data is updated once a day.
CAUTION: the MicroSD must be inserted into the device for backup and restore
procedures
If the device is replaced, these settings can be copied to a new Touch
module as follows:
1.
Remove the micro-SD card from the Touch module being replaced
2.
Insert it into the new Touch module
3.
Access the "Backup and restore" menu and restore the configuration.
INFORMATION
Used to view device information
7 7 8 8 9 9
1
2
3
4
5
6
7
8
9
0
3
NAME DIRECTORY
and confirm you wish to save.