2.2 Technical Description (page 3, fig. 1)
1
Control panel
2
Cover
3
Right side wall
4
Front wall
5
Air outlet grille
6
Air inlet grille
7
Fluff screen
8
Inside front wall
9
Storage blocks
10 Cover plate
11 Thermal insulation
12 Floor thermal insulation
13 Mixing air flap
14 Air duct
15 Cable duct
16 Air guidance assembly
17 Heating element
18 Fan
19 Safety temperature regulator for discharge (N5)
20 Safety temperature regulator for charging (N4)
21 Safety temperature limiter (F1)
26 Wall holder
A1 Electronic charging control unit (page 12)
V4 Operating and fault indicator
X16 Control signal adapter 4-stage
X17 4-stage charging factor reducer
2.2.1. Function
The storage blocks are heated up by the heating elements between the rows of storage blocks.
Charging is set continuously with the charging control unit (selector knob fig. 17)
Start and duration of the charging time are determined by the responsible electricity supply
company.
Two built-in safety temperature regulators (19, 20) and a safety temperature limiter (21) prevent
overheating of the unit. Whilst the safety temperature regulators switch on again automatically,
the safety temperature limiter must be switched back on by the technician by pressing in the knob
in the middle of the limiter after eliminating the cause of the error.
The heat stored in this way is then discharged with the aid of a fan, also partly through the heater
surface. In this case, the room air is sucked in through the air inlet grille (6) by the fan (18) and
blown through the air ducts of the storage blocks (9) which heats them up.
Before being output through the air outlet grille (5) the hot air generated in this way is mixed via
two mixing air flaps with colder room air so that the emitted air does not exceed the maximum
permissible temperature. The position of the mixing air flap and thus the
mixing ratio of the air is controlled by a bi-metal controller.
2.2.2 Reducing the Output
By moving or removing bridges at the terminals, the output which is wired to 100% at the factory
can be reduced in connection with a charging factor reduction on the charging control unit by
3 levels (see page 12).
The dimensioning of the line cross sections and the fusing should correspond to the maximum
possible output of the unit.
A single-phase connection may be made according to the "Technical connection conditions" of
the electricity supply company only up to 2 kW (WSP 1810).
Reducing the charging factor
The electronic charging control unit (A1) contains the plug-in bridge X17 with which the charging
factor of the storage unit can be selected in 4 stages (positions I, II, III or IV) in connection with the
variable connecting lead. Four-stage charging factor adaptation (100 / 90 / 80 70 %). A charging
factor of 100 % (Position I) is pre-selected at the factory.
If the plug-in bridge is plugged to another pin array, this gives a reduced charging factor (switch-
off temperature of the electronic charging control unit is reduced).