Herunterladen Inhalt Inhalt Diese Seite drucken

Important Note; What To Do When - AEG WSP 1210 F Gebrauchs- Und Montageanweisung

Wärmespeicher flach-baureihe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

For the User and the Fitter

1.5 Important Note

Keep these instructions in a safe place, pass on to the new owner in case of a change of ownership.
Make them available to the specialist in the case of repair work.

What to do when . . . ?

• the storage heater
does not get hot
• the storage heater
housing should get
extraordinarily
hot even in mild
weather
For the User
Check whether . . .
. . . the selector knob is set to
position 3.
. . . the corresponding fuses in
your fuse box are defective or
the FI switch has switched off.
Eliminate the cause!
If the following day the
storage heaters have still not
heated up, call a specialist.
Check whether . . .
. . . the fan can be switched on
with the room temperature
regulator.
If not, call a specialist.
. . . the fluff screen in the air inlet
grille is blocked.
Eliminate cause as described
in section 1.4.1!
For the specialist
Check whether . . .
. . . the control of the heating
element contactor is OK.
. . . there is a voltage at terminals
L1/L2/L3.
. . . whether the safety temperature
limiter (F1) has triggered.
"CLIC"
Check whether . . .
. . . the room temperature
regulator
has switched on and
voltage is applied at terminal
LE.
. . . the fans are turning.
. . . the safety temperature
regulator (N5, see page 3,
fig. 1) in the air outlet has
switched off.
. . . the control signal Z1 of the
charging control unit is
applied at terminal A1/Z1 in
the storage heater.
25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis