Herunterladen Inhalt Inhalt Diese Seite drucken

AEG WSP 1210 F Gebrauchs- Und Montageanweisung Seite 31

Wärmespeicher flach-baureihe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

For the Fitter
Power adaptation according to rated charging time
By moving or removing bridges at the terminals, the output can be adapted to the rated charging
time specified by the electricity supply company.
Heating element model
Rated charging time
Connection variants (kW)
Model
WSP 1210 F
WSP 1810 F
WSP 2410 F
WSP 3010 F
WSP 3610 F
WSP 4210 F
WSP 4810 F
100 % P
(series wiring)
Unit rating plate
Observe the labelling on the rating plate and the circuit diagram!
After connecting electrically, the box corresponding to the connection rating and rated charging
time of the unit on the rating plate and the circuit diagram in these installation instructions
should be marked with a smear-proof ballpoint pen.
2.5.3 Unit Ready for Operation
Cleaning the unit (fig. 13 and 14)
The open unit must be cleaned after installation and insertion of the storage blocks.
The fans and the air guidance assembly must be removed for this.
• Unscrew and remove the air guidance assembly (16).
• Lift and remove the fan (18) after loosening (not removing) the screws at the front of the
support brackets (pay attention to cable laying!).
In some units, the discharge temperature control unit (19) including support plate must be
unscrewed.
Make sure the wires are not damaged when setting down the removed parts.
• Clean the floor plate and fan (avoid damage to lamellas!). Then re-install the fans, possibly the
temperature limiter and the air guidance module (correct cable laying!).
Close the unit (fig. 15 and 16)
• Place the inside front wall including thermal insulation with the side edging on the supports at
the bottom, press the unit on top and screw together
(in the WSP 4210 F and WSP 4810 F, another screw must be screwed in the middle);
• Hang in the right side wall at the bottom, tilt up, hang in at top and fix with screw; (reverse
order see 2.5.1 – disassembly right side wall fig. 6)
• Hang in front wall at top, swing to the heater at the bottom and fix with 2 screws (always use
the two inside threaded holes) (fig. 15);
• Screw on the air outlet grille, screwing the screws hand tight and then back about 1 turn
(fig. 16);
• Place the air inlet grille at an angle on the lugs in the heater base, swing round at the top and
snap in behind the air outlet grille (fig. 16).
8h
1.2
1.8
2.4
3.0
3.6
4.2
4.8
91.6 % P
rated
8h
9h
10h
1.1
1.0
1.65
1.5
2.2
2.0
2.75
2.5
3.3
3.0
3.85
3.5
4.4
4.0
83.3 % P
rated
rated
33

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis