Circuit diagram WSP 1210 - 4810 F
A1:
Electronic charging control unit
B1:
Brick temperature sensor - charging
E1 - E6:
Heating element (storage heater)
F1:
Safety temperature limiter
F2:
Fuse (250 V / 2 A slow-blow)
K1:
Thermal relay
M1 - M3:
Fan - discharge
N4:
Temperature limiter - charging
N5:
Temperature limiter - discharging
R1:
Adjuster – charging (selector knob)
V4:
Pilot lamp operation emergency
operation
X1:
Mains terminal
X2:
Terminal
X3:
DC terminal 0.91 – 1.43 V
X16:
Control signal adapter 4-stage
X17:
Output reducer 4-stage
electron. discharge
control unit
electron. charging control unit
DC signal
Charging control signal
Series circuit
100 % P
rated
3/N/PE AC 50 Hz 400 V
3/N/PE AC 50 Hz 400 V
36
Special accessory
not included in delivery scope, mark the respective accessory if installed
A2:
B2:
R2:
S2:
E8:
N2:
N3:
S1:
Note the permissible rating of the room temperature regulator
when installing the supplementary heater (E8)!
AC-signal 230 V
Charging control signal
91,6 % P
83,3 % P
rated
rated
3/N/PE AC 50 Hz 400 V
Integr. room temperature regulator 2-position
Integr. room temperature regulator proportional
Electronic discharge control unit
Room temperature sensor discharge
Adjuster discharge (selector knob)
ON/OFF switch room temperature regulator
Supplementary heater
Supplementary heating element
Temperature regulator – supplementary heater
Temperature regulator – supplementary heater
ON/OFF switch – supplementary heater
*
Control circuit
3/N/PE AC 50 Hz 400 V
1/N/PE AC 50 Hz 230 V
when external RT is connected
*
75 % P
100 % P
rated
3/PE AC 50 Hz 400 V
1/N/PE AC 50 Hz 230 V
For the Fitter