14.4
Cleaning the water intake
screen
1
► Unscrew the connector (1) of the water con‐
nection.
► Remove water intake screen (2) from the con‐
nector.
► Rinse out the water intake screen (2) under
running water.
► Insert water intake screen (2) into the connec‐
tor.
► Attach the connector (1) and tighten it by
hand.
14.5

Cleaning the water filter

The water filter must be disassembled to clean it.
1

17 Troubleshooting

17.1

Correcting faults in the pressure washer

Fault
The pressure washer
does not start alt‐
hough the spray gun
trigger is squeezed.
42
1
2
2
3
Cause
The mains plug of the connecting
cable or extension cord is not plugged
in.
The circuit-breaker (fuse) or the resi‐
dual current circuit breaker has trip‐
ped. There is an electrical overload or
a fault in the circuit.
The fuse rating of the socket is too
low.
The extension cord has an incorrect
cross-section.
► Remove the seal (1) from the filter housing (3).
► Take the filter (2) out of the filter housing (3).
► Rinse out the seal (1) and the filter (2) under
running water.
► Grease the gasket (1) with a fitting grease.
► Reassemble the water filter.

15 Maintenance

15.1

Maintenance intervals

Maintenance intervals depend on the ambient
conditions and the operating conditions. STIHL
recommends the following maintenance inter‐
vals:
Monthly
► Clean water intake screen.

16 Repairing

16.1
Repairing the pressure washer
The user cannot personally repair the pressure
washer and accessory.
► If the pressure washer or accessory is dam‐
aged: Do not use the pressure washer or
accessory. Consult a STIHL servicing dealer.
Remedy
► Plug in mains plug of connecting
cord or extension cord.
► Look for cause of tripping and
remedy it. Engage circuit-breaker
(fuse) or the residual current circuit
breaker.
► Switch off other loads connected to
the same circuit.
► Plug the connecting cable into a
socket with the correct fuse rating,
18.1.
► Use an extension cord with an ade‐
quate cross-section,
15 Maintenance
18.2
0458-004-9821-B