Remote control

The appliances
IVS 100/40
IVS 100/55
IVS 100/75
are equipped with a radio receiver for the remote control
option.
The training time and operation are described in the op-
erating instructions of the remote control.

Shutting down

 Switch off the appliance using the On/Off switch.
 If necessary, dismantle the accessory and rinse it
with water and let dry.
 Empty the vacuuming material container (refer
chapter "Emptying vacuuming material container").
 Vacuum and wipe the appliance inside and outside
with a damp cloth.
 On completion of wet vacuum cleaning: Dry the fil-
ter. Clean the container with a moist cloth and dry
it off.
Emptying the vacuuming material container
 Switch off the appliance and secure it using the
parking brakes at the guide rollers.
 Unlock and lower the container.
 Switch on device to avoid releasing dangerous
dusts.
 Pull out the vacuuming material container from the
appliance using the handle that has been provided
for the purpose.
 Replace the dust bag (see chapter "Disposal sys-
tem").
Note
The vacuum material container can be lifted by cranes
at the handle. Maximum load for crane transport: 50 kg.
CAUTION
Risk of injury and damage! Note the total weight of the
vacuum material container when transporting with a
crane. Do not overload the container. Observe instruc-
tions on lifting with a crane.
Storing the Appliance
 Wrap the mains cord around the cable holder.
 Wind the suction hose around the sliding bow.
 Insert the floor nozzle and the suction pipe into their
respective holder.
 Place the appliance in a dry room and secure it
from unauthorized use.
CAUTION
Risk of injury and damage! Observe the weight of the
appliance when you transport it.
When transporting in vehicles, secure the appliance ac-
cording to the guidelines from slipping and tipping over.
CAUTION
Risk of injury and damage! Note the weight of the appli-
ance in case of storage.
This appliance must only be stored in interior rooms.
Wet filters and internal parts of the liquid container
must be dried before storage.

Care and maintenance

Warning
First remove the mains plug before doing any job on the
vacuum cleaner.
DANGER
First pull out the plug from the mains before carrying out
any tasks on the machine.
Adhere to the local accident prevention guidelines and
safety notes.
Dust extracting machines are safeguards for the pre-
vention or elimination of hazards defined in the regula-
tions of BGV A1.
In order to carry out maintenance work, the user
must disassemble, clean and service the unit, in so
far as this is possible without endangering mainte-
nance personnel and other persons. Suitable pre-
cautions include decontamination before the unit is
disassembled. Precautions must be taken for local
filtered forced air ventilation at the place where the
unit is disassembled, the cleaning of the mainte-
nance surface and suitable protection of the per-
sonnel.
The outside of the unit should be cleaned thorough-
ly and any harmful substances removed. Alterna-
tively, a sealed coating may be applied before the
unit is removed from the danger area. All unit parts
are to be considered contaminated when they are
removed from the danger area. To avoid distribu-
tion of the dust, you must take the appropriate
measures.
In the framework of maintenance and repair work
all contaminated objects that cannot be cleaned
satisfactorily must be disposed of. Such objects
must be disposed of in impermeable bags in ac-
cordance with the valid provisions for the disposal
of such waste.
The motor/suction turbine casing may only be dis-
assembled by specialist personnel.
The interior of the motor/suction turbine casing may
only be cleaned by specialist personnel.
During the transport and maintenance of the appli-
ance the extraction opening is to be closed with the
connection socket.
WARNING
Safety equipment for preventing hazards must be ser-
viced and maintained regularly. This means that the
manufacturer's staff or persons trained by the manufac-
turer must check the equipment for proper functioning at
least once a year, i.e. check for leaks, filter damage,
functioning of the controlling elements, etc.
– 6
EN
Transport
Storage
17