Herunterladen Inhalt Inhalt Diese Seite drucken

HEIDENHAIN EIB 8000 Betriebsanleitung Seite 25

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Accessories
The following items are optionally available and can
additionally be ordered from HEIDENHAIN:
Accessories
Encoder input
Adapter cable, D-sub 15-pin – MDR26
(1 m)
Adapter cable, D-sub 15-pin – MDR26
(3 m)
The following items are optionally available and can also
be ordered from the manufacturers indicated below:
Accessories
Encoder input
Connector – MDR 26
PDL (PCIe x4)
Cable 0.5 m to 7 .0 m
SMA cable
(for SynClk and PTM, single-ended, LVTTL 50 Ω)
Differing propagation times of the SynClk
and PTM inputs or outputs can result in
measuring errors.
Use the same cable lengths for the
inputs and outputs of SynClk and PTM,
respectively
Synchronization, single-ended
Synchronization, single-ended
Front trigger (M9, 8-pin)
Connector shielded
Cable 2 m with shielded
connector
Cable 5 m with shielded
connector
HEIDENHAIN | EIB 8000 | 09/2018
ID
1038743-01
1038743-03
Order number
3M Series 10120
Molex 074546040x
Various manufacturers
RG223/U
Various manufacturers
RG316/U
Binder 99 0425 1008
Binder 79 1425 1208
Binder 79 1425 1508
3.3
Installation
The product is intended for installation in a 19-inch
electrical cabinet. A height unit is required for the
installation.
NOTICE
Failure of fan!
A fan failure may result in overheating of the product,
and therefore to malfunctions or destruction.
Ensure that the product may be easily accessed
during operation
Ensure proper ventilation
Ensure that the vents are free from obstructions,
maintain a distance > 15 mm and do not block the
airflow
The fan can be monitored by interrogating a
status word that can report a failure of the
fan. The temperature of the product can be
interrogated and is monitored internally.
For more information, refer to the User's
Manual for Application Development.
For information on the mounting attitude, see "C" on the
front fold-out page.
Insert the product in the electrical cabinet and fasten
it with four M6 x 12 screws (min. x 6 mm, max. x 16
mm). The screws are not included in delivery
For the hole locations, see "D", Page 151.
27