Configuration menu
6.1

Automatic operation

In automatic mode, the temperature is controlled in accordance with the
set heating profile. Manual changes are activated until the next point at
which the profile changes. Afterwards, the defined heating profile will
be activated again. To activate the automatic mode, please proceed as
follows:
Press and hold down the menu button (G) to open the
configuration menu.
Select "Auto" via the plus and minus buttons (E + F) in the menu.
Confirm with the menu button.
To confirm, the symbol flashes twice and the device changes back to
automatic mode.
6.2

Manual operation

In manual mode, the temperature is controlled in accordance with the
current temperature set via the push-buttons (E + F). The temperature
remains activated until the next manual change. To activate the manual
mode, please proceed as follows:
Press and hold down the menu button (G) to open the
configuration menu.
Select "Manu" via the plus and minus buttons (E + F) in the menu.
Confirm with the menu button.
To confirm, the symbol flashes twice and the device changes back to
manual mode.
6.3

Offset temperature

As the temperature is measured on the radiator thermostat, the
temperature distribution can vary throughout a room. To adjust this, a
temperature offset of ±3.5 °C can be set. If a nominal temperature of e.g.
20 °C is set but the room presents with only 18 °C, an offset of -2.0 °C
needs to be set. An offset temperature of 0.0° is set in the factory settings.
To adjust the offset temperature, please proceed as follows: