Herunterladen Inhalt Inhalt Diese Seite drucken

Ecler CA200Z Bedienungsanleitung Seite 63

Digitaler mischverstärker zur integration in av-systemer
Vorschau ausblenden Andere Handbücher für CA200Z:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CHIME_MELODY
<Input=I3:I6>
CHIME_VOL
<Input=I3:I6>
XSELECT
<Input=I1:I6>
XLEVEL
<Input=I1:I6>
ZONE_LABEL
<Zone=ZA:ZD>
ZONE_STEREO
<Zone=ZA:ZD>
ZONE_MUTE
<Zone=ZA:ZD>
ZONE_VOL
<Zone=ZA:ZD>
GEQ_ACTIVE
<Zone=ZA:ZD>
GEQ_GAIN
<Zone=ZA:ZD>
XOVER_ACTIVE
<Zone=ZA:ZD>
XOVER_TYPE
<Zone=ZA:ZD>
XOVER_FREQUENCY
<Zone=ZA:ZD>
COMPRESSOR_ACTIVE
<Zone=ZA:ZD>
COMPRESSOR_THRESHOL
<Zone=ZA:ZD>
D
COMPRESSOR_RATIO
<Zone=ZA:ZD>
COMPRESSOR_ATTACK
<Zone=ZA:ZD>
COMPRESSOR_RELEASE
<Zone=ZA:ZD>
Gets the current CHIME MELODY selected for the TALKOVER function in PAGER
mode
Gets the current CHIME MELODY VOLUME (dBx10) adjusted for the TALKOVER
function in PAGER mode
<Zone=ZA:ZD>
Gets the current CROSSPOINT SELECT status (ON (input active) or OFF (input
muted)) for the specified INPUT at the specified output zone
<Zone=ZA:ZD>
Gets the current CROSSPOINT LEVEL (mix level) for the specified INPUT at the
specified output zone
Gets the current LABEL (name) for the specified output zone
Gets the current STEREO link status (ON or OFF) the specified output zone
Gets the current MUTE status (ON or OFF) for the specified output zone
Gets the current VOLUME for the specified output zone
Gets the current GRAPHICAL EQUALIZER status (ON or OFF) for the specified
output zone
<Band=B1:B10>
Gets the current GAIN (dBx10) of one BAND (B1 to B10) of the GRAPHICAL
EQUALIZER for the specified output zone
Gets the current CROSSOVER FILTER status (ON or OFF) for the specified output
zone
Gets the current CROSSOVER FILTER TYPE (LP or HP) for the specified output
zone
Gets the current CROSSOVER FILTER FREQUENCY (Hz) for the specified output
zone
Gets the current COMPRESSOR status (ON or OFF) for the specified output zone
Gets the current COMPRESSOR THRESHOLD LEVEL (dBx10) for the specified
output zone
Gets the current COMPRESSOR RATIO (x100) for the specified output zone
Gets the current COMPRESSOR ATTACK TIME (milliseconds x10) for the
specified output zone
Gets the current COMPRESSOR RELEASE TIME (milliseconds x10) for the
specified output zone
63

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis