4. Commissioning, operation
For the first 25 minutes after connecting the battery, the LED function is activated.
LED colour
Mode
Blinks once
Blue
Cyan
ON for the duration of the join
procedure
Cyan
Blinks once
Red
Blinks twice
Red
Blinks twice
Green
Blinks twice
WARNING!
Danger for electronic components through electrostatic discharge (ESD)
Improper handling of electrical components can destroy or damage them.
When the sensor housing is open, e.g. when connecting or changing the battery pack, sufficient ESD
protection must be ensured.
Do not touch the PCB and electrical components.
Before removing the plastic case, touch the grounded metal part of the case, or an alternative adjacent
grounded metal object (e.g. radiator or pipes), in order to discharge any static from the body.
Avoid contact between the electronics and clothing.
Notes on the sending characteristic
In order to achieve the best possible transmission quality, the radio link from the terminal device to the receiving
gateway should be as free of barriers as possible.
The signal strength is from slightly to severely affected by concrete walls, metal shield, enclosures and hilly
landscapes.
For the best possible transmission performance of the antenna, no metal objects, such as pipelines, may be closer
than 10 cm to the antenna.
With installation, pay attention to the sending characteristic of the instrument as well as the information from the
following figure:
WIKA operating instructions, models PEW-1000 and PEW-1200
Meaning
Internal communication between radio and sensor PCBs
LoRaWAN
®
join procedure running
LoRaWAN
®
join procedure successful
LoRaWAN
®
join procedure not successful
LoRaWAN
®
data transfer not successful (confirmed message)
LoRaWAN
®
data transfer successful (confirmed message)