The installation of the fireplace insert must be carried out in accordance with the provisions
of the applicable standards, the requirements of the construction law and the applicable fire
standards. Detailed rules on structural safety, fire safety and safety of use are contained in
the regulations and building regulations in force in the country. The installation and com-
missioning of the fireplace insert should be carried out by an installation company with the
appropriate authority and experience for this purpose. The installer should confirm in the
warranty card that the installation work has been performed correctly by signing and stam-
ping the warranty. In the event of failure to comply with this requirement, the purchaser
loses the right to warranty claims against the manufacturer of the fireplace insert.
Location
The fireplace insert must be installed on a non-combustible substrate with a minimum
thickness of 30 cm, and the floor at the fireplace door must be secured with a strip of non-
-combustible material with a minimum width of 50 cm. The safe distance of the combustible
components from the glass shall be at least 100 mm. 150 cm