Herunterladen Inhalt Inhalt Diese Seite drucken

Shutting Down; Accessories - Kärcher WOMA Vacujet 2500 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
 Adjust the ground clearance for the brush or sealing lip pre-
tension by means of the spacer sheets.
Note
During operation with the brush, the suction openings in the cas-
ing are closed.
If a subsequent change to sealing lip is to take place, the suction
openings must be opened by taking out the plugs.
Operation with suction
With normal requirements, the equipment with one brush is ade-
quate. A vacuum cleaner with the following performance data en-
sures sufficient tightness.
– for suction lengths < 15 m: 775 m
– for suction lengths > 15 m: 980 m
 The device can be equipped with a sealing lip for highest de-
mands.
Illustrations on Page 2
 Switch on the high-pressure water jet machine.
 Open air stop cock.
 Operate the high-pressure pushbutton and keep it down.

Shutting down

Illustrations on Page 2
 By releasing the high-pressure pushbutton the appliance
switches itself off.
 Switch off the high-pressure water jet machine.
 Close the air stop cock.
Power
Admissible recoil force
Total width
Working width
Weight
Speed nozzle bar
Air requirement (at 6 bar)
Tyre pressure
Number of nozzles
Suitable nozzles
Suction connection
Compressed-air maintenance unit material no. 9.872-124.0.
The brushes rotate; water is dispensed to the brushes depending
on the setting. Depending on the selected programme, the suc-
tion turbine is running.
Squeeze or kink the suction hose coupling sleeve.
Open wastewater hose cover.
Coil the battery charging cable around the cable hooks.
8
/h (5.5 kW)
3
/h (15 kW)
3
Start up
Vacujet 2500
max. 2500 bar at 15 l/min
max. 2000 bar at 20 l/min
N
max.250
mm
440
mm
225
kg
36
1/min
max. 2500
m³/min
0,522
bar
max. 7
max. 8
Shape 21
mm
Suction connection DN 70
 Store accessories in a frost protected room immediately after
finishing the operation.
DANGER
Switch off the high-pressure water jet machine and depressurize
the high-pressure system prior to any work on the device and the

accessories.

Maintenance to be carried out after 250 operating
 Relubricate -WOMA material no. 9.872-024.0 - at the lubricat-
ing points using a grease gun. Loosen threaded pins first.
Use transmission grease FAG Arcanol Multitop WOMA mate-
rial no. 9.890-521.0.
 Have accessories checked for proper condition every 12
months by the customer service.
Maintenance to be carried out after 350 operating
DANGER
For safety reasons, this maintenance must only be performed by
the customer service.
For this maintenance task the device must be dismounted.
 Clean and relubricate bearings, renew if necessary.
 Clean and relubricate gearwheels, renew if necessary.
 Check all seals, shaft seal and especially the high-pressure
seal and renew if necessary.
DANGER
For safety reasons, malfunctions may only be rectified by the cus-
tomer service or especially trained personnel.
Specifications
Accessories
3
-
EN
Storage
Maintenance and care
hours
hours
Troubleshooting

Werbung

Inhaltsverzeichnis
loading