Herunterladen Inhalt Inhalt Diese Seite drucken

SDMO Diesel 6000 A Silence C5 Benutzer- Und Wartungshandbuch Seite 24

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 47
As a safety measure, maintenance should be performed on the generating set regularly and carefully by people who have the
necessary experience and are equipped with suitable tools, in respect of current regulations. The maintenance operations to be
carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for generating sets operating with
fuel and oil which conform to the specifications given in this manual. The maintenance intervals can be shortened depending on the
generating set's operating conditions and requirements. It is important to note that the warranty shall not be valid if generating set
maintenance has not be performed correctly.
5.1
Reminder of use
Ensuring maintenance is performed regularly and correctly will guarantee safety and performance. The oil, filter elements and,
where present, the spark plug, are consumables which must be in good condition for the unit to operate correctly.
Replace them regularly as often as is needed (the reference for ready-to-use maintenance kits is given in the table of
technical specifications where applicable). The warranty becomes void in the event of failure to respect the maintenance
recommendations. For any questions about a special operation, please contact your nearest agent who will advise and help you.
5.2
Maintenance intervals table
The maintenance frequency is given as an indication only and is for devices using fuel and oil complying with the specifications
given in this manual. The maintenance intervals can be shortened depending on the unit's operating conditions and requirements.
Perform the maintenance operations at the indicated due dates even if the number of hours' operation has not been reached. The
warranty will be invalidated if maintenance of the unit has not been performed correctly.
Operation to be carried out:
Clean the unit
Unit
Check the battery charge
Change
Oil
Replace the filter
Fuel
Replace the filter
Air filter
Replace
Part numbers of parts to be used during maintenance:
*
If KOHLER oil is used, the interval can be extended to 150 hours of operation.
5.3
Performing the maintenance operations
1.
Shut down the unit and wait at least 30 minutes for it to cool.
2.
Disconnect the "–" terminal on the battery.
3.
Open the unit's top cover and access door.
4.
Carry out maintenance in accordance with the information given in this manual and, to avoid the risk of damage to the unit,
only use original parts or their equivalent.
5.
Close the unit's top cover and access door.
5.3.1
Replace the oil filter and change the oil
The used oil and filter must be recycled or eliminated according to the local regulations in force. In order for the drain operation to
be more effective, it is advisable to run the generating set for around ten minutes before the drain operation in order to make the oil
more fluid.
Drain the oil:
1.
Place a suitable container under the oil drain screw (B4), then remove the oil filler cap (A7) and the oil drain screw.
2.
Open the oil drain tap (A14-B5).
3.
Once the oil has drained completely, close the oil drain tap and tighten the oil drain screw.
Replace the oil filter:
4.
Using a suitable wrench, remove the used oil filter (A15-B6) and discard it.
5.
Clean the oil filter holder and coat the new oil filter seal with clean engine oil.
6.
Fit the new oil filter, tightening it by hand.
Fill up the oil:
7.
Unscrew the oil filler cap.
8.
Using the dipstick (A6-B1), to regularly check the level, top up with oil that complies with the technical specifications in this
manual.
Too much or too little oil can damage the generating set.
9.
Refit the oil filler cap.
:
Finish the operation
10. Wipe away any traces of oil with a clean cloth and check that there are no oil leaks.
1086_EN.docx
After
3 months/
5 hours
50 hours
X
X
X
X
X
X
X
3499231004548
20/280
Section 5. Generating set maintenance
In hours, months or years, whichever comes first
Every
Every
6 months/
2 years/
100 hours
200 hours
X
Major service
X
to be carried
X*
out by one of
X
our agents.
X
France:
0.806.800.107
X
(
call charge
3499231004548
Every
2 years/
500 hours
Major service
to be carried
out by one of
our agents.
France:
0.806.800.107
)
(
)
call charge
2021-07-02

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Diesel 6000 a silence avr c5Diesel 6500 ta silence c5Diesel 6500 ta silence avr c5

Inhaltsverzeichnis