8 Installation

* If using PP 45 EO, a max. of 8 radio sensors
and a max. of 4x PP 45 RC (master) can be
taught-in.
7.2 Combinations K20–K27 (RLS 45 O)
Ventilation unit,
sensor
Combination no.
K20
K21
K22
K23
K24
K25
K26
K27
Additional functions
K25: Exhaust air mode possible with
1x PPB 30 O + RLS 45 O. To start, press the op-
tional ventilation level button for > 2 seconds.

7.3 EnOcean combinations K30 (radio)

Ventilation
PP 45 RC
unit, sensor
Combination
DS 45 RC
no.
K30
Any
Additional functions
K30: Any number provided they are within range.
Supply air only from 2 PP 45 RC units.
*Only wired exhaust air units are permitted (do
not use RC exhaust air units).
8 Installation

8.1 Installation information

• Only use slide-in module in wall sleeve with ap-
propriate incline to the exterior wall → Shell in-
stallation instructions.
• The slide-in unit (slide-in module + extension
duct) must be appropriate for the wall thickness,
to avoid a ventilation short-circuit (lack of air).
To ensure this, shorten the extension duct ac-
curately.
PP 45 O / PP 45 K PPB 30 O
Fan interface
Fan1/ Fan2
2
3
4
5
6
PP 45 O /
PP 45 K
RLS 45 K + 
PP 45 EO
Fan interface
Fan1/ Fan2
1
2
3
Exhaust air
units, e.g.,
ER... / ECA... *
PP 45 ACT
1
• With wall thicknesses of 500-790 mm, use the
optional PPB 30 VS extension kit. When in-
stalling, use the centring ring provided for the
extension.
• Only mount internal cover on flat surfaces and
without any distortion.
• The appropriate mounting material must be
supplied on site.
• For prescribed connection lines → Connection
and wiring diagrams [} 80]:
• Grid connection and 230 V input: Type NYM-J
5G1, 5 mm²
• Control cables: type J-YSTY, 0.8 mm, 4 wires.
Max. 25 m from star point, up to star point max.
4 m
External sensors
Internal sensor
(PP 45 HY, CO2,
PP 45 HYI
VOC) and LT
RS 485 bus
I2C bus
0-3
0-3
0-3
0-3
0-3
0-3
0-3
0-3
Exhaust air
units, e.g.,
ER... / ECA...*
230 V input
0-1
0-1
0-1
0-1
0-1
0-1
0-1
0-1
EnOcean ex-
ternal wireless
sensors
EnOcean wire-
less
0-8
35