Technical information

10
Technical information

10.1 Tech data

Technical characteristics
Rated output
Rated Voltage
Fuse protection / circuit breaker
Minimum cable cross-sectional area
Water mixed at rated output with
temperature increase of;
12 °C up to 38 °C (without flow limiter)
12 °C up to 38 °C (with flow limiter)
12 °C up to 60 °C
Minimum appliance start-up flow rate
Minimum appliance start-up pressure
Application field for water with specific
electrical resistance at 15 °C.
Rated pressure
Maximum allowable inlet temperature
Flow limiter
Maximum impedance at connection point
1) Depending on the installation, a larger cable cross-section may be required.
2) The first time the appliance is commissioned, the minimum water flow rate should be 3.5 l/min.
3) The pressure drop in the mixer should be added to this value.
Table 10 Technical characteristics
28
Unit
TR5001 11/13..
11
KW
11
V
400 V3~
A
25
1)
2
mm
2.5
l/min
6.0
l/min
5.0
l/min
3.3
2)
l/min
2.5
3)
MPa
0.04 (0.4)
(bar)
cm
≥ 1 300
MPa
1.0 (10)
(bar)
°C
55
l/min
5.0
(colour)
(Orange)
0.141 0.132
TR5001 15/18/21..
13
15
18
13
15
18
400 V3~
25
25
25
4
7.1
8.1
9.8
5.0
7.6
3.8
4.4
5.3
2.5
0.04 (0.4)
≥ 1 300
1.0 (10)
55
5.0
7.6
(Orang
(White)
e)
0.088
Tronic 5000 – 6721830067 (2021/06)
TR5001 21/24/27..
21
21
24
21
21
24
400 V3~
32
32
40
6
11.6
11.6
13.0
7.6
6.2
6.2
7.1
2.5
0.04 (0.4)
≥ 1 300
1.0 (10)
55
7.6
(White)
(Yellow)
0.064
27
27
40
14.6
9.4
7.9
9.4

Quicklinks ausblenden: