Explanation of symbols and safety instructions
WARNING
Danger of electric shocks!
In the event of a malfunction or water
leak in the appliance,
▶ Immediately turn off the electrical
supply to the appliance.
▶ Turn off the cold water supply to the
appliance immediately.
H Installation
These installation instructions are for
experts specialised in water
installations, electrical engineering and
heating techniques. All instructions from
the manuals must be observed. Failure
to comply with these instructions can
result in material damage, personal
injury and danger to life.
▶ Read the installation instructions
(heat generator, heating regulator,
etc.) before installation (
chapter 5).
▶ Comply with the current legal
provisions in the country in which the
appliance is installed, and those of
the local energy and water supply
companies.
▶ Install the appliance into a cold-water
circuit containing water for human
consumption (closed circuit).
▶ The installation must only be carried
out by an authorised contractor.
▶ Always switch off the electric current
before opening the appliance.
4
▶ To avoid dangerous situations, repairs
and maintenance may only be carried
out by an authorised technician.
▶ The appliance is suitable for
connection to plastic pipes tested by
DVGW.
▶ This appliance is of protection classI
and must be connected to the
protective conductor.
▶ The appliance must be permanently
connected to the electrical
installation. The cross sectional area
of the wire must be equivalent to
the power to be installed (
chapter 10).
WARNING
Danger of electric shocks!
The appliance's grounded pipes can
make it seem that the appliance is
grounded.
▶ The appliance must be connected to
the protective conductor cable.
▶ To guarantee compliance to relevant
safety regulations, an all-pole
separator must be fitted during
installation, according to chapter 10.
The contact opening must be at least
3 mm.
▶ Make sure that the maximum and
minimum inlet water pressure is
compliant with the value specified by
the manufacturer ( chapter 10).