Technical Data; Installation Regulations; Regulations; Transport - Bosch BT 50 HP Installations- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
2.5

Technical data

Storage tank
storage volume (heating water)
flow V
, V
1
2
return R
, R
1
2
measuring point M
1
maximum heating water temperature
max. heating water working pressure
Additional data:
weight (empty)
weight (full)
Table 11
3

Installation regulations

3.1

Regulations

This appliance must be installed and serviced only by a competent
person in accordance with the current:
• IEE Regulations, Building Regulations,
• Building Standards (Scotland) (Consolidation),
• Building Regulations (Northern Ireland),
• local water by-laws,
• Health and Safety Document 63S (the Electricity at Work Regulations
1989,
• IS813 (Eire)
• and other local requirements
• Where no specific instruction is given, reference should be made to
the relevant codes of Practice:
– BS7074:1 : Code of practice for domestic and hot water supply
– EN:12828 : Central heating for domestic premises
4

Transport

4.1

Means of transport

DANGER: Risk of injury from carrying heavy weights!
▶ Do not try to lift or carry the storage tank alone.
5

Fitting

5.1

Fitting the temperature sensor

▶ Slide the temperature sensor into the sensor pocket, use heat paste
to ensure a good contact. Fit the sensor cable into the cable retaining
clip with a small loop to ensuring the cable is not pulled tight.
Ensure that the sensor area has contact with the sensor
pocket area for the sensor's full length.
Sensor positions:
• M
= Measuring point for flow temperature sensor top
1
BT 50 HP – 6 720 805 225 (2013/03)
L
50
R ¾
R ¾
▶ Protect the storage tank against tilting and transport to its installation
R ½
location standing upright and in its packaging.
°C
95
▶ Do not remove the storage tank packaging before it is in the
bar
3
installation location.
kg
24
kg
74
Fig. 21 Transport of the hot water storage tank by suitable means
4.2
▶ Observe minimum clearances.
▶ Place storage tank on an even and load-bearing ground.
▶ In damp rooms: put storage tank on a platform.
▶ Recommend minimum clearance of 25mm around the tank.
▶ Ensure you have adequate access to the drain valve.
• C
1
▶ Lay the sensor lead through open cable retaining clip, ensuring that a
small loop of cable exists between the clip and the sensor, and close
the clip firmly on the cable.
CAUTION: Damage from inappropriate protection
during transport!
▶ For transport, use appropriate means,
e. g. a sack truck or pump truck with a tension belt.

Industrial location

NOTICE: Protect from freezing!
▶ Place storage tank in a frost-proof room.
▶ Ensure the tank is frost protected.
▶ Insulate pipes with class O insulation.
NOTICE: Damage from corrosion!
▶ Use the storage tank in sealed systems only.
= Sensor cable retaining clip
For information on the sensor refer to the
documentation of your heat pump or of the control unit.
Installation regulations
6720803559-03.1Wo
19